EMI High Wall Air Handler WCP User Manual

Specifica tion s and p erformance, Wcp high wall air handler

Advertising
background image

Web: http://www.enviromaster.com

Enviromaster International LLC

ProduCt dEsCrIPtIon

The WCP is a contemporary design, chilled water air handler
that combines attractive appearance in any decor, with the

highly efficient conditioning of small to mid size commercial
or residential spaces. Equipped with unit mounted infrared
compatible controls, optional hand held remote also
available.

Units provide up to a nominal 30,000 Btuh of cooling. Electric
heat options are available for up to 5KW of supplemental
heat. It can be paired with a matching capacity chilled water
supply. This all American made unit offers ease of installation,
operation and service.

Factory Installed Controls/Components:

• Relays and connections for chilled water supply

• Unit mounted digital controls as standard:

– Large ¾” LCD display
– Anti-short cycle protection
– Fan purge (fan remains on for 60 seconds after

heat/cool call dropped for improved efficiency)

• Auto/high/low fan operation

• Low Volt transformer

notE: Auto fan operation automatically selects
fan speed according to heating or cooling demand.
Constant fan operation is manually selected high or
low speed.

Materials of Construction:

• Cabinet (available in designer white with grey discharge

vanes) fabricated of cold roll steel with structural stiff-
eners

• Air inlet panel made from high impact polystyrene with

perforated steel grille

• Discharge grille constructed of high temperature Noryl

• Condensate drain pan made from galvanized steel

(G90U) with anti-corrosion coating

oPtIonaL EquIPmEnt

• Hand held infra-red remote controller (a separate hand

held remote controller used to command the on-board
controls).

notE

: Unit mounted controls are fully functional

without the remote controller.

• Field installed condensate pump

• 24V remote thermostat with controls & relays

• Chilled water control valve (N/C 24V ac, 20VA max. or

8 VA max. on units with condensate pumps)

• Electric heat with automatic reset high temperature

cutout and redundant high temperature fuse link.

InstaLLEr suPPLIEd ItEms

• Power wiring & low voltage wiring

• Mounting screws and fasteners

• Chilled water & condensate piping

WCP

HigH Wall air Handler

Specifica

tion

S

and

p

erformance

P/N# 240003248 Rev. A [06/08]

aIr HandLEr standard FEaturEs

2 PiPe CHilled Water Fan Coil

Nominal Capacities: 9000, 12000,

15000, 18000, 24000, 30000 Btuh

WCP CaPaCItIEs

model

nominal

Capacaties

total

Capacity

sensible

Capacity

Fluid

temp.

Fluid

Flow

Pd

Ft. H

2

0

09/12

9,000

7,375

6,732

45

1

0.8

10,801

8,272

45

2

3.8

13,270

9,279

45

3

8.0

12,000

8,387

7,189

40

1

0.8

12,481

8,950

40

2

3.9

15,643

10,304

40

3

8.1

15 /18

15,000

15,624

13,477

45

2

4.4

19,761

15,367

45

3

9.1

18,000

17,724

14,379

40

2

4.5

23,073

16,763

40

3

9.3

24/30

24,000

20,563

17,564

45

3

2.3

29,031

21,178

45

6

8.3

32,320

22,539

45

9

17.7

30,000

23,600

18,887

40

3

2.4

34,400

23,423

40

6

8.4

38,790

25,351

40

9

17.9

Advertising