Marwin Valve UT Series Pneumatic Actuators User Manual

Marwin Valve Accessories for water

Advertising
background image

INSTRUCTION AND MAINTENANCE MANUAL

MARWIN UT DESIGN 2011 PNEUMATIC ACTUATORS

3170 Wasson Road * Cincinnati, OH 45209 USA
Phone 513-533-5600 * Fax 513-871-0105
e-mail:

[email protected]

www.marwinvalve.com

Page 1 of 10

Bulletin IM-UT Dsgn2011_1114

Note: the numbers in parenthesis refer to the components in the exploded view of page 3 for UT-0 thru UT-6.5 and page 4 for UT-7 and UT-8.

CAUTION:

Remove dust from the actuator that may cause sparks; clean periodically to prevent accumulation of dust on the actuator.

Do not hit the actuators with metallic objects, as this may give off sparks.

TABLE OF CONTENTS:

1. WARNING

2. SERVICE CONDITIONS

3. FUNCTION

4. STORAGE

5. MAINTENANCE

6. EXPLODED VIEW

7. DISASSEMBLING

8. ASSEMBLING

9. ADJUSTMENT

10. REVERSING PISTONS

11. IDENTIFICATION OF ACTUATOR VERSIONS

1 Warning

The installation and the maintenance of pneumatic actuators must be assigned to trained and qualified personnel.

The use of the actuators outside the allowed temperature and pressure ranges may cause damage to the internal and external components.

Prior to any installation and maintenance of the actuator, shut-off and disconnect any kind of power or air supply.

Disassembling spring return type actuators may cause severe injuries due to compressed springs inside. The maintenance must be performed by

qualified expert personnel in full observance of the instruction described at paragraph 6. Otherwise the actuator has to be returned to MARWIN.

2

Service conditions

AIR SUPPLY: dehumidified or lubricated air (standard). Other non-corrosive gases or fluids are a possible alternative option, if compatible to the

materials of the actuator components (internal parts and lubricant).

WORKING PRESSURE: 40 psi minimum to 115 psi maximum (2,7 bar minimum t o 8 bar maximum

TEMPERATURE:

- STANDARD: - 4°F to + 185°F (-20°C to + 85°C) - NBR gaskets, Kluber Tribostar 1 EP (Centoplex2 EP) Lithium / Mineral grease

- HIGH temperature option: - 4°F to +302°F (-20°C to +150°C) - FKM (Viton) gaskets, Kluber Petamo GHY 133N Polyurea / Mineral grease

- LOW temperature option: - 40°F to +185°F (-40°C to +85°C) - silicone gaskets, Kluber Isoflex Topas NB52 barium Complex / Synthetic grease

Notes:

1. For high or low temperature options, special grease is used as the lubricant and may alter the torque generated by the actuator. For

further information please refer to MARWIN.

2. Mixing grease types is not recommended.

ROTATION: 0°- 90°, adjustable ±5° in both end positions (double adjustment).

LUBRICATION: The actuators are equipped with filled-for-life lubrication for normal service conditions.

OPERATING TIME: Refer to the technical documentation. The operating time depends on various parameters such as air supply pressure,

capacity of the air supply installation (size of piping and control equipment), type of valve and fluid, selected safety factor, temperature etc.

Advertising