Single Zone Expander

(RP128EZ01)

The RISCO RP128EZ01 is a Single Zone Expander that enables to connect any detector to RISCO system

BUS. Using the BUS connection you can ease your installation by connecting any detector in parallel

connections from any point along the wiring route. In addition you can define any detector with one of

the following zone terminations supported by the panel: NO, NC, EOL, DEOL, TEOL.
The following instructions explain how to connect to the RP128EZ01 the ProSYS.

Notes:

1. Up to 32 Single Zone Expanders can be installed on the ProSYS main BUS.
2. Up to 128 Single Zone Expanders can be assigned to the ProSYS using the BUS Zone Expander.

The following instructions explain how to connect a detector to the ProSYS BUS using the RP128EZ01.

Installation

1. Set the RP128EZ01 ID number (1-32) using DIP switches 1-5.

 SW1 (1 - 5): ID switches. Defines the Single BUS Zone Expander ID number
 SW1 - 6: Not used

ID

DIP - 1 DIP - 2

DIP - 3 DIP – 4 DIP - 5

ID

DIP - 1

DIP - 2

DIP - 3

DIP - 4

DIP - 5

1

Off

Off

Off

Off

Off

17

Off

Off

Off

Off

On

2

On

Off

Off

Off

Off

18

On

Off

Off

Off

On

3

Off

On

Off

Off

Off

19

Off

On

Off

Off

On

4

On

On

Off

Off

Off

20

On

On

Off

Off

On

5

Off

Off

On

Off

Off

21

Off

Off

On

Off

On

6

On

Off

On

Off

Off

22

On

Off

On

Off

On

7

Off

On

On

Off

Off

23

Off

On

On

Off

On

8

On

On

On

Off

Off

24

On

On

On

Off

On

9

Off

Off

Off

On

Off

25

Off

Off

Off

On

On

10

On

Off

Off

On

Off

26

On

Off

Off

On

On

11

Off

On

Off

On

Off

27

Off

On

Off

On

On

12

On

On

Off

On

Off

28

On

On

Off

On

On

13

Off

Off

On

On

Off

29

Off

Off

On

On

On

14

On

Off

On

On

Off

30

On

Off

On

On

On

15

Off

On

On

On

Off

31

Off

On

On

On

On

16

On

On

On

On

Off

32

On

On

On

On

On

2. Wire the RP128EZ01 BUS wires Red, Black (COM), Yellow(BUS) and Green (BUS) to the

ProSYS BUS.

Notes:

For maximum operation stability, it is best NOT to exceed a total of 300 meters (1000 feet) of wiring from the
ProSYS BZ1 to the ProSYS panel or to the BUS Zone Expander.

 Wiring RP128EZ01 to the Main BUS