RISCO Group RP512EZ16 User Manual

Risco 16 zone expander

Advertising
background image

EN

RISCO 16 Zone Expander

(RP512EZ16)

The RISCO 16 Zone Expander enables to expand the number of wired zones in the ProSYS Plus.

DIP Switches Settings

Switch 1-5

Defines the Zone
Expander ID
number.

Switch 6-7

Not Applicable

Switch 8:
Tamper Bypass

Instead of a short
between the
TMP/COM
terminal block)

Zone Termination

Note:

:

The RP512EZ16 enables to define the end-of-line resistance of its zones. Selection is done via the panel keypad or
Configuration Software with the following available options

RTTE Compliance Statement:
Hereby, RISCO Group declares that this equipment is in compliance with the essential requirements and
other relevant provisions of Directive 1999/5/EC.
For the CE Declaration of Conformity please refer to our website: www.riscogroup.com.

No

EOL

DEOL

No

EOL

DEOL

No

EOL

DEOL

TEOL

0

Customized

5

3.74K 6.98K

10

3.3K

3.3K

1

2.2K

2.2K (Default) 6

2.7K

2.7K

11

5.6K

5.6K

2

4.7K

6.8K

7

4.7K

4.7K

12

2.2K

1.1K

3

6.8K

2.2K

8

3.3K

4.7K

13

2.2K

4.7K

4

10K

10K

9

1K

1K

14

4.7K

6.8K

12K

Technical Information

Current Consumption

20 mA typical, 100mA Maximum

Main Panel Connection

4-wire BUS, ≤300 m from Main Panel

Dimensions

16.5 cm x 6.6 cm x 1.8 cm