RISCO Group 2-Button Panic Keyfob , 2-way User Manual

Agility wireless 2-way remote control

Advertising
background image

E N G L I S H

F R A N Ç A I S

Introduction

The Agility 2-Way remote control is an 8 button rolling code wireless transmitter designed
for remote system operation. The remote control is typically used to set (arm), unset (disarm),
activate devices and get system status. Being bi-directional enables each command that is
sent to the panel to receive a reply status from the panel and indicate the status to the user
via the colour LEDs. For higher security, commands can be de

¿ned to be activated with a

4 digit PIN code.
Check with your installer regarding the de

¿nitions of the remote control.

* If the 1

st

LED changes to orange it indicates a low battery condition.

For full installation instructions refer to our website www.riscogroup.com

Common Operations:

UK
Tel: +44-161-655-5500
[email protected]

U.S.A
Tel: +1-631-719-4400
[email protected]

ITALY
Tel: +39-02-66590054
[email protected]

BRAZIL
Tel: +1-866-969-5111
[email protected]

SPAIN
Tel: +34-91-490-2133
[email protected]

CHINA
Tel: +86-21-52-39-0066
[email protected]

FRANCE
Tel: +33-164-73-28-50
[email protected]

POLAND
Tel: +48-22-500-28-40
[email protected]

BELGIUM
Tel: +32-2522-7622
[email protected]

ISRAEL
Tel: +972-3-963-7777
[email protected]

RISCO Group Limited Warranty

E S P A Ñ O L

Operation

Quick

High Security Mode

Set (Full) (Away Arm)

> Code

Set (Partial) (Stay Arm)*

> Code

Unset (Full Disarm)

> Code

System Status

for 2 seconds for 2 seconds > Code

Output control A/B/C

/ /

/ /

for 2 seconds

for 2 seconds > Code

Panic Alarm

+ simultaneously for 2 seconds

Clear Operation

>

Introduction

La télécommande bidirectionnelle de l’Agility est un transmetteur 8 boutons à codes tournants
conçue pour commander le système à distance. Elle est utilisée pour armer, désarmer, activer
des périphériques et obtenir l’état du système. Le fait d’être bidirectionnelle lui permet, pour
chaque exécution de commande envoyée à la centrale, de recevoir un retour sur le statut de
la centrale, et de l’af

¿cher via la couleur des LEDs. Pour une plus grande sécurité, les

commandes peuvent être dé

¿nies pour n’être activées qu’avec un code PIN à 4 chiffres.

Demandez à votre installateur les options de votre télécommande.

Status LED Indications:

Operation

1

st

LED* 2

nd

LED*

(Send command) (Receive Status)

Full Setting (Away)

Green

Red

Part Set (Stay Arm)

Green

Orange

Unset (Disarm)

Green

Green

Alarm

Green

Flash LED

Introducción

El mando bidireccional de la Agility es un transmisor vía radio de 8 botones de código
variable (“rolling code”) diseñado para manejar el sistema remotamente. El mando
normalmente se usa para armar, desarmar, activar dispositivos y conocer el estado
del sistema. Al ser bidireccional, permite que cada comando que se envía al panel
reciba una respuesta del estado desde el mismo, indicando al usuario dicho estado
por medio de un código de colores del LED. Para mayor seguridad, los comandos se
pueden de

¿nir para tener que activarse con un código PIN de 4 dígitos.

Consulte con su instalador las de

¿niciones del mando.

Status BUZZER Indications:

Sound Status

1 beep Con

¿rmation

3 beep Error

5 beep Alarm

Agility Wireless

2-Way Remote Control

4

\

?

4

\

?

Pour les instructions complètes d’installation, reportez vous à notre site web
www.riscogroup.com

Fonctions basiques:

Fonction

Rapide

Séquence avec code

Armement total

> Code

Armement partiel*

> Code

Désarmement (total)

> Code

Etat du système

Appui long Appui long > Code

Contrôle de sortie A/B/C / /

/

/

Appui long Appui long > Code

Alarme panique

+ simultanément pendant 2 secondes

Annuler commande

>

LED:

Fonction

1

ère

LED*

2

ème

LED*

(Envoie de commande) (Réception de l’état)

Armée totalement

Verte

Rouge

Armée partiellement

Verte

Orange

Désarmée

Verte

Verte

Alarme

Verte LED rouges clignotante

BUZZER:

Son

Etat

1 bip

Con

¿rmation

3 bips

Echec commande

5 bips

Alarme

4

\

?

4

\

?

Operaciones habituales:

Función

Rápido

Secuencia con código

Armado Total

> Código

Armado Parcial

*

> Código

Desarmado Total

> Código

RISCO Group and its subsidiaries and af

¿liates ("Seller") warrants its products to be free from defects in

materials and workmanship under normal use for 24 months from the date of production. Because Seller
does not install or connect the product and because the product may be used in conjunction with products
not manufactured by the Seller, Seller cannot guarantee the performance of the security system which uses
this product. Seller's obligation and liability under this warranty is expressly limited to repairing and replacing,
at Seller's option, within a reasonable time after the date of delivery, any product not meeting the speci

¿cations.

Seller makes no other warranty, expressed or implied, and makes no warranty of merchantability or of

¿tness

for any particular purpose.In no case shall seller be liable for any consequential or incidental damages for breach
of this or any other warranty, expressed or implied, or upon any other basis of liability whatsoever. Seller's
obligation under this warranty shall not include any transportation charges or costs of installation or any liability
for direct, indirect, or consequential damages or delay. Seller does not represent that its product may not be
compromised or circumvented; that the product will prevent any personal injury or property loss by burglary,
robbery,

¿re or otherwise; or that the product will in all cases provide adequate warning or protection. Buyer

understands that a properly installed and maintained alarm may only reduce the risk of burglary, robbery or fire
without warning, but is not insurance or a guaranty that such event will not occur or that there will be no personal
injury or property loss as a result thereof. Consequently seller shall have no liability for any personal Minjury,
property damage or loss based on a claim that the product fails to give warning. However, if seller is held liable,
whether directly or indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless
of cause or origin, seller's maximum liability shall not exceed the purchase price of the product, Mwhich shall
be complete and exclusive remedy against seller. No employee or representative of Seller is authorized to
change this warranty in any way or grant any other warranty.

WARNING: This product should be tested at least once a week.

CAUTION: risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteriess according to local regulations.

FCC Note:

This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
a) Reorient or relocate the receiving antenna.
b) Increase the separation between the equipment and receiver.
c) Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
d) Consult the dealer or an experienced radio/TV technician.

FCC ID: JE4RW132KF2
IC: 6564A-RW132KF2
This device complies with FCC rules part 15. Operation is subject to the following two condition:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired
operation.

FCC Warning
The manufacturer is not responsible for any radio or TV interference caused by unauthorized modi

¿-

cations to this equipment. Such modi

¿cations could void the user's authority to operate the equipment.

* Si la 1ère LED est orange, cela indique une condition de batterie basse pour la télécommande.

* For Part Setting with no entry delay press the key for two seconds.

*

Pour l’armement partiel sans délai d’entrée, appuyez sur la touche pendant deux secondes.

[France only]:

Déclaration de conformité

Par la présente, RISCO Group déclare que la série Agility des centrales et accessoires a été
conçue conformément aux normes:

RTC 50131-3 ,EN50131-3, Grade 2

EN50130-5, Environmental class II (IP31, IK 06)

EN50131-6, Type C

Organisme de certi

¿cation

AFNOR CERTIFICATION: 11 rue Francis de Pressensé
93571 LA PLAINE SAINT-DENIS Cedex, http://www.marque-nf.com
CNPP Cert: BP 2265, 27950 ST MARCEL, http://www.cnpp.com

Déclaration de Conformité RTTE
Par la présente, RISCO Group déclare que cet accessoire est en conformité avec les conditions
essentielles et à d’autres dispositions appropriées de la directive 1999/5/EC. Pour obtenir la
copie complète de conformité, référez-vous à notre site web : www.riscogroup.com
Ce produit répond aux exigences du référentiel de certi

¿cation NF324-H58 pour la

classi

¿cation 2 boucliers, et de la RTC 50131-3.

p

Advertising