RISCO Group IR Beam 72 Outdoor Detector User Manual

Ir beam 72, Installation guide

Advertising
background image

‐1‐

 

IR Beam 72

(Beam 7225/Beam 7250/Beam 7275)

Installation Guide

1. Introduction

The IR Beam 72 outdoor detectors employ twin beams with advanced optics and four selectable channels, providing reliable detection. 

2. Layout

Cover
Screw
Wire Entry 

4

Channel Option Switch 
Optical Axis Monitor Jack (Receiver) 
Optical Axis Rotation 
Reflector and Filter 
Bracket and Base Attaching Holes 
Optical Axis Windows 
Optical Axis Screw 
Response Speed VR (Receiver) 
Terminal Block 

13

LED
Sense LED 
D‐belt for pole mounting  
(purchased separately ‐ P/N: RBM72P00000A) 

Bracket 

3. Mounting Location

4. Installation Method

1. Mount the transmitter and receiver within maximum range. 

2. In case the received signal is low, install within rotation angle range 
of the reflector.

3. Avoid direct sunlight (facing 
sunrise or sunset) or 
headlamps. 
 

4. Avoid obstacles (flowerpots, 
laundry, pets) between receiver and 
transmitter. 

5. When installing several detectors or cross installation to avoid 
collision install according to the following diagram:

 

 

6. Do not install on unstable 
surfaces. 

 

7.  After mounting, adjust optical 
axis and conduct a walk test. 

 

1. To remove front cover, 
unscrew front bottom screw. 
 

 

 

3. Mount on desired wall or pole 
and connect wires through wire 
entry (see terminal block). 
 

 

 

 

 
4. Connect the wire through the 
upper terminal block. Replace 
the bracket and fixing screw. 
 

 

2. To separate bracket from 
detector, unscrew bottom screw. 
 

 

 When mounting two 

brackets on one pole, install a 
pair of D‐belts at the upper and 
lower parts and install another 
D‐belt in the middle for equal 
mounting height. 

 

 

 
5. Adjust the optical axis and 
conduct a walk test. Then, 
replace front cover. 
 

 

Advertising