RISCO Group Vitron WL Glass Break Detector User Manual

Vitron, Vitron vitro n vitron vi tron, Installation instructions

Advertising
background image

RISCO Group Limited Warranty

Installation instructions

RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal
use for 24 months from the date of production. Because Seller does not install or connect the product and because the product may be used in
conjunction with products not manufactured by the Seller, Seller can not guarantee the performance of the security system which uses this
product. Sellers' obligation and liability under this warranty is expressly limited to repairing and replacing, at Sellers option, within a reasonable
time after the date of delivery, any product not meeting the specifications. Seller makes no other warranty, expressed or implied, and makes no
warranty of merchantability or of fitness for any particular purpose. In no case shall seller be liable for any consequential or incidental damages for
breach of this or any other warranty, expressed or implied, or upon any other basis of liability whatsoever. Sellers obligation under this warranty
shall not include any transportation charges or costs of installation or any liability for direct, indirect, or not be compromised or circumvented; that
the product will prevent any persona; injury or property loss by intruder, robbery, fire or otherwise; or that the product will in all cases provide
adequate warning or protection. Buyer understands that a properly installed and maintained alarm may only reduce the risk of intruder, robbery or
fire without warning, but is not insurance or a guaranty that such will not occur or that there will be no personal injury or property loss as a result.
Consequently seller shall have no liability for any personal injury, property damage or loss based on a claim that the product fails to give warning.
However, if seller is held liable, whether directly or indirectly, for any loss or damage arising from under this limited warranty or otherwise,
regardless of cause or origin, sellers maximum liability shall not exceed the purchase price of the product, which shall be complete and exclusive
remedy against seller. No employee or representative of Seller is authorized to change this warranty in any way or grant any other warranty.

WARNING

: This product should be tested at least once a week.

CAUTION

: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to local regulations

5. Swivel Mounting

3. Mounting Location

1. General Description

The Wireless VITRON is an advanced microprocessor
based Acoustic Glass Break detector. Using advanced
glass-breaking pattern analysis of both Low Frequency
"Flex" & High Frequency "Shatter" channels, the
Wireless VITRON detects the breaking of most
common types of framed glass panes while ignoring
false alarms

Main Features

• Up to 9m detection range

• Suitable for most common glass types: plate,

tempered, laminated and wired glass

• Minimum size for all types of glass: 30cm x 30cm

(12'' x 12'').

• Wall and Front cover Tamper protection

Type of glass

Thickness

Plate
Tempered
Laminated

3.2 mm – 6.4mm

(1/8''-1/4'')

Wired 6.4

mm

(1/4'')

• Wireless VITRON will not alarm if glass pane is

broken from inside or glass is dropped on floor.

• Full remote test using RG-65 Glass Break Simulator,

without the need to open the unit

• Optional ceiling/wall mount swivel adaptor for

optimal mounting and performance (supplied with
the Wireless VITRON).

2. Installation Procedure

When installing the Wireless VITRON with the supplied swivel
mounting adaptor, maximum installation flexibility and
performance is achieved.
To install the swivel mounting adaptor perform the following:
1. Remove the PCB from the Wireless VITRON back plate
2. Open the swivel mounting adaptor knockouts (4, Fig 7).
3. Attach the swivel mounting adaptor to the back plate using

the two supplied screws (1, Fig 8).

4. Mount the Wireless VITRON on the required location (wall

or ceiling) using the supplied screws (2, Fig 8). Do not
tighten the screws.

5. Adjust the detector so it will face the protected glass.
6. Tighten the bolts to the final torque.

2

1

Fig. 8

For optimal performance the Wireless VITRON should
be mounted as nearly opposite to the glass area to be
protected, as shown in Fig 3.
Opposite Wall –Mounted (For optimal results,

Wireless VITRON is centered opposite glass, see
Fig. 3).

VITRON

Fig. 3

Ceiling Mounted (for optimal results Wireless

VITRON is centered and directed towards protected
glass, using the supplied swivel adaptor, see fig. 4).

VITRON

VITRON

Fig. 4

Corner Mounted (choose corner opposite glass to

be protected see fig. 5).

VITRON

VITRO N

VITRON

VI TRON

Fig. 5

Side wall mounted (not recommended due to the

fact that the Wireless VITRON is not opposite the
glass - see range versus angle diagram (Fig 2). Test
detection carefully at both ends of glass using
RG-65 Tester (see fig. 6).

VITRON

VITRON

Fig. 6

Notes:

Do not mount Wireless VITRON on same wall as the
protected glass.
Avoid installing the Wireless VITRON near sources of loud
noise or vibrations (air conditioners, fans, compressors,
stereos, etc).
Avoid defining the Wireless VITRON as a 24 hour zone.
The Wireless VITRON should always be installed in addition
to standard motion detectors.

4. Mounting

6. PCB Main Components

ANTENNA

SW2

SW1

J4

J3

BA

TT

1

RF POWER

HIGH/LOW

SUPERVISION

15/65 Min.

©

RISCO

LED

2

6

5

7

10

8

3

1

9

4

# Description

1

PCB

2

Battery holding holders

3

J3 – RF Power selector

4

J4 – Time supervision selector

5

Front Cover tamper switch

6

Back Plate cover tamper switch

7

Microphone

8

Antenna

9

Indication LED

10

Positioning hole

7. Transmitter/Receiver Communication link setup

The Wireless VITRON has 3 operation modes:

Normal : Any loud sounds such as clapping, whistling or key-
jingling should produce a flash of the VITRON 's LED. This
verifies that the Wireless VITRON is active. During active
supervision, there is no transmission. To save power
consumption the LED is activated up to 800 times per day.

Alarm: On detection of framed glass being broken from
outside the LED will light continuously for 2 seconds and an
alarm transmission is sent

Test: See test paragraph

8. Testing the Wireless VITRON

Testing under Test mode

Testing should be performed using RISCO Group's RG65
Glass Break Simulator which has been specially designed
and calibrated to give accurate range test results.

Note:

All tests should be conducted under worst case conditions. All
sounds should be generated behind curtains or blinds.

Step 1: Entering the test mode

The Wireless VITRON enter the test mode if one of the
following is performed:
1. After closing the front cover - the Wireless VITRON will

enter into test mode for 2 minutes.

2. Using the RG65 tester - Position the tester at a distance of

1 meter from the Wireless VITRON . Set the lower selector
switch on the RG65 tester to CODE setting and press the
operation button on the tester. The Wireless VITRON will
blink once every 3 seconds, lasting for a period of two
minutes.

Step 2: High frequency (audio) test

Position the Glass Break Simulator at the farthest point on the
protected glass and face it into the room. Set lower selector to
GLASS setting and upper to type of glass to be simulated.
Generate glass-break sound by pressing operating button.
Verify that the Wireless VITRON LED is lit for 2 seconds and
ALARM message is transmitted while the red LED is on.

1. Open the Wireless VITRON cover using a flat

screwdriver.

2. Open the required mounting knockouts, according to

the type of installation (corner, flat or swivel
mounting, see Fig. 7)

3. Use the detector's back plate as a template and

mark the drilling holes on the required position.

Notes:

Remove the PCB only if corner mounting or optional swivel

mounting

adaptor is used.

1

5

4

2

3

1

6

Fig 7: Wireless VITRON Mounting Knockouts

# Description

1

Corner mounting knockout

2

Wall/Flat mounting knockout

3

Back tamper knockout

4

Swivel mounting adaptor knockouts

5

Cover attaching notches

6

Snap and fastening screw

4. If a back tamper protection is required open the back

tamper knockout (3, Fig. 7)

5. Secure the back plate to the wall using the supplied

screws. Snap back the PCB (if removed).

Insert battery in place according to the correct polarity
(polarity marks - on PCB).

Range of coverage:

Wireless VITRON range of coverage depends on the type
of glass (see Table 1) and the installation angle between
the Wireless VITRON and the glass (see Fig 1)

Plate

Tempered, Laminated, Wired,

Size Thickness

Max.

Range

Size Thickness Max.

Range

Minimum
50x50cm
(20"x20")

9m (30ft)

Minimum
30x30cm
(12''x12'')

3.2 – 6.4mm

(1/8''-1/4'')

6m (20ft)

Minimum
30x30cm
(12''x12'')

6.4mm

(1/4'')

6m

(20ft)

Table 1: Wireless VITRON range of coverage

Angle

(degrees)

Percent of

maximum range

0 10

12 95
30 87
45 70
60 50
75 25
90 0

Note:

To improve detection, It is highly recommended to use
a swivel adaptor, especially for ceiling and wall
installations

75°

60°

45°

30°

15°

WIRELESS

VITRON

Fig 1: Percentage of Maximum Range as a function of
angle between Wireless VITRON and glass.

Verify that the distance between the Wireless VITRON
and the furthest point on the protected glass does not
exceed the maximum specified range taking into
account the reduced range due to angle (see Fig 2).

Fig 2: Angle between Wireless VITRON and glass

Other factors affecting range:

• There should be no obstructions between the

Wireless VITRON and the protected glass.

• Curtains and blinds may reduce the effective range.

• Sound absorbing materials in the protected area

may reduce the range.

Advertising