RIGOL DS6000 Series User Manual

Rp1010h高压示波器探头, Warning, Cleaning

Advertising
background image

用 户 手 册
User’s Guide

© 2013 RIGOL Technologies, Inc. All Rights Reserved.

RP1010H高压示波器探头

High Voltage Probe for Oscilloscope

北京普源精电科技有限公司

RIGOL Technologies,Inc.

邮箱

E-mail:[email protected] 网址Website:www.rigol.com

Warning

Do not attempt to take measurements from sources when

the chassis or return lead is not ground.

This ground connection is critical to the safety operation of

the probe. Failure to make this connection may result in

personal injuries or damages to the probe or voltmeter. This

connection must be made before the probe tip comes into

contact with the high voltage and must not be removed

until after the probe tip has been removed.

Do not connect the ground clip to the high voltage source or

the probe tip to the ground for any reason.

BEFORE turning the high voltage on, make sure that no

part of your body is in contact with the device.

Remembering that the voltage being measured is 1000

times greater than the voltmeter reading.

When the measuring voltage are DC 8 to 10 KV, or

AC rms 5 to 7 KV or AC peak 15 to 20 KV, do not

exceed 60 sec on each measurement. You can break off for

5 minutes at least during the measurement. Otherwise

overheating will affect the measurement accuracy even

damage the probe. Disconnect the probe tip from the high

voltage source BEFORE removing the ground clip lead.

Clean only the exterior probe body and cables. Use a soft

cotton cloth lightly moistened with a mild solution of

detergent and water. Do not submerge any portion of the

probe at any time.

Dry the probe thoroughly before any voltage measurement.

Make sure the probe is free from any solvents or solvent

fumes as these can case deterioration to the probe body and

cables.

When the measuring voltage is under

the followings. Each measurement

should be within 60 sec. You can break

off for 5 minutes at least during the

measurement.

DC: 8 ~ 10 KV

AC RMS: 5 ~ 7 KV

AC PEAK: 15~ 20 KV

当测量电压为下述情况时,每
次测量时间不得超过60秒。期
间需断开并等待散热至少5分
钟。

直流:

8 ~ 10 KV

交流

有效值:5 ~ 7 KV

交流

峰峰值:15 ~ 20 KV

!

Cleaning

性能指标

Specifications

最大工

作电压

Max. Working Voltage

DC: 0 ~ 10 KV DC
AC: pulse ≤ 20 KV peak to peak
AC: sine wave ≤ 7 KV rms

信噪比

Signal/Noise

DC ≥ 60 dB (1 KHz),

50 dB (1 MHz)

带宽

Bandwidth

DC ~40 MHz (-3 dB)

衰减比例

Division Ratio

1:1000

上升时间

Rise Time

8.8 ns

输入阻抗

Input Impedance

100 MΩ ± 5%

输入电容

Input Capacitance

3.0 pF ± 0.5 pF

补偿范围

Compensation Range

5 pF ~ 50 pF

线长度

Cable Length

2.0 meter (± 0.2 M)

温度系数

Temperature Coefficient ≤ 200 PPM /℃

精确度

Accuracy

DC

±

3% (DC to

10 KV)

AC

±

3% (1 KHz/1 KV )

-3dB 40 MHz

安全认证

Safety App.

CE

操作温度

Operating Temperature 0 ~ 50℃

存储温度

Storage Temperature

-20 ~ +70℃

重量

/尺寸 Weight / Dimension

250 g /

Φ

75 x 340

L

mm

S M1 0 2 0 0 0 2 5 7 9

Advertising