Elkay EDF20 User Manual

Installation/care/use manual, Important, Installer

Advertising
background image

96540C (Rev. G - 3/01)

EDF20C

Installation/Care/Use Manual

To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE

INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLA-

TION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE

CODES. After installation, leave these instructions inside the fountain for future reference.

10

SEE FIG. 3

INSTALLATION INSTRUCTIONS

1. Wall should already be framed for the fountain using the positioning dimensions shown in Figure 1. Shown dimensions pertain to

installation location (framing must support up to 150 lbs. weight).

2. Install rough-in plumbing as shown in Figure 1. Connecting lines to be unplated copper. Run supply water inlet line and connect to

a service stop (not provided). Turn on supply water and flush thoroughly. Close water supply.

3. Secure the fountain to the wall using bolts and washers (not provided). Tighten securely.

4. Make water supply connections from service stop to the fountain. Turn on water supply and check for leaks. Newly installed

water supply line should be insulated after leak check is completed.

5. These products are designed to operate on 20-105 PSIG supply line pressure. If inlet pressure is above 105 PSIG, a pressure

regulator must be installed in the supply line. Any damage caused by reason of connecting these products to supply line pressures

lower than 20 PSIG or higher than 105 PSIG is not covered by warranty.

6. Check stream height from bubbler. Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, remove

items 7 and 8 (See Figure 3) and adjust the screw on the regulator (Item 5). Clockwise adjustment will raise stream height and

counter-clockwise will lower stream height. For best adjustment stream should be approximately 1" (25mm) above the bubbler

guard. (See Figure 2).

TROUBLE SHOOTING AND MAINTENANCE

1. Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from

orifice with a small round file not over 1/8" diameter or a small diameter wire. CAUTION: Do not file or cut orifice materials.

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO

WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY

OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A

FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN

THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER

MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE

OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.

Installer

11, 12

9

Advertising