Advanced operation] command-based control, Controlling the monitor with a computer (lan) – Sharp PN-60TW3 User Manual

Page 61

Advertising
background image

61

E

[Advanced operation]
Command-based control

You can control the monitor using RS-232C commands

(see page 45) via terminal software and other appropriate

applications.

In order to use this function, enable a connection to the

monitor through the web browser.

Read the manual for the terminal software for detailed

instructions.

(1) Connect the computer to the monitor.

1. Specify the IP address and data port number and

connect the computer to the monitor.

When connection has been established successfully,

[ Login:] is returned as response.

2. Send the user name set in the SECURITY settings (see

page 57).

• Send [User name] + [ ].

• If the user name is not set, send [ ].

• When the transmission is successful, [ Password:]

is returned as response.

3. Send the password set in the SECURITY settings (see

page 57).

• Send [Password] + [ ].

• If the password is not set, send [ ].

• When the transmission is successful, [OK ] is

returned as response.

(2) Send commands to control the monitor.

• The commands used are the same as those for RS-

232C. Refer to the communication procedure (see

page 42) for operation.

• Usable commands are provided in the RS-232C

command table (see page 45).

(3) Disconnect the connection with the monitor and

quit the function.

1. Send [BYE ].

When the transmission is successful, [goodbye] is

returned and the connection is disconnected.

TIPS

• Connection is automatically disconnected when the

time specified in AUTO LOGOUT TIME elapses over a

no-communication period.

Controlling the Monitor with a computer (LAN)