Others, Controlling the monitor with a pc (rs-232c) – Sharp PN-U423 User Manual

Page 38

Advertising
background image

38

E

Others

Function

Command Direction

Parameter

Reply

Control/Response contents

*

VOLUME

VOLM

WR

0-31

0-31

MUTE

MUTE

WR

0-1

0-1 0: OFF, 1: ON

-

TEMPERATURE SENSOR

DSTA

R

0 Internal temperature normal

1 Internal temperature abnormal has occurred and the monitor is in standby mode
2 Internal temperature abnormal occurred (To delete the information of temperature

abnormal, turn off the main power.)

3 Internal temperature abnormal has occurred and backlight brightness is dimmed
4 Temperature sensor abnormal

TEMPERATURE ACQUISITION

ERRT

R

Value Returns the temperature at the temperature sensors in the following format.

[Sensor 1] [Sensor 2]
Indicates a temperature sensor abnormality when “126” is returned.

CAUSE OF LAST STANDBY MODE

STCA

W

0

Initialization

R

0 No detectable error has occurred
1 Standby mode by POWER button
2 Main power off by the main power switch
3 Standby mode by RS-232C or LAN
4 Input signal waiting mode by No Signal
6 Standby mode by abnormal temperature
8 Standby mode by SCHEDULE setting

20 Standby mode by OFF IF NO OPERATION setting

TIPS

• With some commands, the settings of an item are not continuous. In that case, the entered parameter will be set to the

closest setting.

(Example) When the settings are “...45, 50, 55...” :

The entered parameter is “50”, “51”, or “52”, “50” is set.

The entered parameter is “53”, “54”, or “55”, “55” is set.

• With some commands, the number set in the menu screen may differ from the number of the parameter.

Controlling the Monitor with a PC (RS-232C)