Electric Dryer

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

RECESSED AREA AND CLOSET INSTALLATION

EXHAUST VENTING

EED4300V
EED4400V

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. W10150612

04-18-08

43

³⁄₈"

(110 cm)

*26"

(66 cm)

29"

(73.66 cm)

A

15

¹⁄₄"

(38.74 cm) 43 ³⁄₈"

(110 cm)

*27

³⁄₄"

(70.5 cm)

29"

(73.66 cm)

B

22

³⁄₄"

(57.8 cm)

43

³⁄₈"

(110 cm)

13

³⁄₄"

(34.9 cm)

*27

³⁄₄"

(70.5 cm)

29"

(73.66 cm)

D

43

³⁄₈"

(110 cm)

*27

³⁄₄"

(70.5 cm)

29"

(73.66 cm)

C

22

³⁄₄"

(57.8 cm)

4"

(10.2 cm)

2.5"

(6.4 cm)

Louvered style

Angled style

4"
(10.2 cm)

4"
(10.2 cm)

Box hood style

A. Recessed area
B. Side view - closet or confined area

C. Closet door with vents

A

B

C

18"
(45.7 cm)

1"
(2.5 cm)

29"
(73.66 cm)

1"
(2.5 cm)

1"
(2.5 cm)

14" max.
(35.6

cm)

27

³⁄₄"

(70.5 cm)

5

¹⁄₂"

(14 cm)

48 in.
(310 cm )

2

2

24 in.
(155 cm )

2

2

3"
(7.6 cm)

3"
(7.6 cm)

For closet installation
with a door, minimum
ventilation openings in
the top and bottom of
the door are required.
Louvered doors with
equivalent air openings
are acceptable.

1. Select the route that will provide the straightest and most direct path outdoors. Plan

the installation to use the fewest number of elbows and turns. When using elbows or
making turns, allow as much room as possible. Bend vent gradually to avoid kinking.
Avoid 90° turns.

2. Determine vent length.

The maximum length of the exhaust system depends upon:

• The type of vent (rigid metal or flexible metal).
• The number of elbows used.
• Type of hood.

See the exhaust vent length chart that matches your hood type for the maximum vent
lengths you can use.

3. Determine the number of elbows you will need.

IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.

In the column listing the type of metal vent you are using (rigid metal or flexible metal),
find the maximum length of metal vent on the same line as the number of elbows.

Vent Length Chart

Number of

90° turns

or elbows

Type of

vent

Box or

Louvered

hoods

Angled

hoods

0

Rigid metal

Flexible metal

64 ft (20 m)
36 ft (11 m)

58 ft (17.7 m)
28 ft (8.5 m)

1

Rigid metal

Flexible metal

54 ft (16.5 m)
31 ft (9.4 m)

48 ft (14.6 m)
23 ft (7 m)

2

Rigid metal

Flexible metal

44 ft (13.4 m)
27 ft (8.2 m)

38 ft (11.6 m)
19 ft (5.8 m)

3

Rigid metal

Flexible metal

35 ft (10.7 m)
25 ft (7.6 m)

29 ft (8.8 m)
17 ft (5.2 m)

4

Rigid metal

Flexible metal

27 ft (8.2 m)
23 ft (7 m)

21 ft (6.4 m)
15 ft (4.6 m)

Electrical: A four-wire or three-wire, single
phase, 120-volt, 60 Hz, AC-only, electrical supply
is required on a separate 15 or 20 amp circuit,
fused on both sides of the line. A time-delay fuse
or circuit breaker is recommended.
Exhaust venting: Exhaust your dryer to the
outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do Not
use plastic or metal foil vent. Exhaust outlet hood
must be at least 12 inches from the ground or any
object that may be in the path of the exhaust.

A. Small Opening

Side-Swing Door

B. Large Opening

Side-Swing Door

C. Wide Opening

Side-Swing Door

D. Wide Opening

Hamper Door

*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for exhaust

vent with elbow.