Estate TGP310T User Manual

Gas range

Advertising
background image

Gas Range

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

CABINET OPENING DIMENSIONS

TGP310T

TGP314T

Gas supply: Use 3/4" (1.9 cm) rigid pipe gas
supply line to the range location. A smaller size
pipe on longer runs may result in insufficient
gas supply. With L.P. gas, piping or tubing size
can be 1/2" (1.3 cm) minimum. If local codes
permit, it is recommended that new flexible metal
appliance connector, design-certified by CSA,
4-5 feet (122-152.4 cm) long, 1/2" (1.3 cm) or
3/4" (1.9 cm) I.D., be used for connecting the
range to the rigid gas supply line. A 1/2" (1.3 cm)
male pipe thread is needed for connection to
pressure regulator female pipe threads. An
individual manual shutoff valve must be located
in the same room, but external to the range.

Electrical: A 120 volt, 60 Hz, AC only, electrical
supply is required on a separate 15-amp circuit,
fused on both sides of the line. A time-delay fuse
or circuit breaker is recommended.

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. W10153329

10-25-07

Cabinet opening dimensions shown are for 25"
(64 cm) countertop depth, 24" (61 cm) base cabinet
depth and 36" (91.4 cm) countertop height.

29-7/8" (75.9 cm)

width

46-1/4"

(117.5 cm)

overall height

24-1/4"

(61.6 cm)

36"

(91.4 cm)

cooktop

height

26-3/4"
(67.9 cm)
depth with
handle

For minimum
clearance to
top of cooktop,
see NOTE.

This shaded area

recommended for

installation

of gas pipe.

This shaded area

recommended for

electrical outlet.

18" (45.7 cm)
min. clearance
upper side
cabinet to
countertop

13" (33.0 cm) max.
upper cabinet depth

30-

¹ ₈" (76.5 cm)

opening width

30" (76.2 cm) min.
cabinet opening width

8"

(20.3 cm)

2"

(5.1 cm)

3"

(7.6 cm)

5"

(12.7 cm)

5"

(12.7 cm)

10" (25.4 cm)

2" (5.1 cm) min.
countertop space to
side wall or other
combustible material

24"

(61.0 cm)

NOTE: 24" (61 cm) minimum when bottom of wood
or metal cabinet is protected by not less than

¹⁄₄"

(0.64 cm) flame retardant millboard covered with
not less than No. 28 MSG sheet steel, 0.015" (0.4
mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper.

30" (76.2 cm) minimum clearance between the top
of the cooking platform and the bottom of an
unprotected wood or metal cabinet.

If installing a range hood or microwave hood
combination above the range, follow the range
hood or microwave hood combination installation
instructions for dimensional clearances above the
cooktop surface.

Advertising