Mounting the da av eq series, Tabletop use, Rack mounting – Extron Electronics DA 6V EQ User Manual

Page 9: Ul rack mounting requirements, Rack mounting procedure, Installation and rear panel

Advertising
background image

DA AV EQ Series • Installation and Rear Panel

DA AV EQ Series • Installation and Rear Panel

Installation and Rear Panel

2-3

3

.

Mechanical loading

— Mount the equipment in the rack

so that a hazardous condition is not achieved due to
uneven mechanical loading.

4

.

Circuit overloading

— Connect the equipment to the

supply circuit and consider the effect that circuit
overloading might have on overcurrent protection and
supply wiring. Appropriate consideration of equipment
nameplate ratings should be used when addressing this
concern.

5

.

Reliable earthing (grounding)

— Maintain reliable

grounding of rack-mounted equipment. Pay particular
attention to supply connections other than direct
connections to the branch circuit (e.g., use of power strips).

Rack mounting procedure

To mount the distribution amplifier on a 6" deep or 9.5" deep
rack shelf,

1

.

If rubber feet were previously attached to the bottom of
the unit, remove them.

2

.

Mount the unit on the rack shelf, using two 4-40 x 3/16"
screws in opposite (diagonal) corners to secure it.

3

.

Install blank panel(s) or other unit(s) on the rack shelf.

4

.

Attach the rack shelf to the rack using the supplied bolts.

6" Deep Rack Shelf

Front false
faceplate
uses 2
screws.

1/2 Rack Width Front False
Faceplate

Use the 2 mounting holes on
opposite corners.

(2) 4-40 x 3/16"
Screws

Mounting a DA AV EQ on a 6" deep rack shelf

Mounting the DA AV EQ Series

The DA AV EQ distribution amplifiers can be set on a table;
mounted on a rack shelf; or mounted through or under a desk,
podium, or tabletop.

The following optional mounting kits are available for the
DA AV EQ Series:

RSB 126

1U, 6" deep basic rack shelf (part #60-604-10)

RSU 126

1U, 6" deep universal rack shelf kit

(part #60-190-10)

RSB 129

1U, 9.5" deep basic rack shelf (part #60-604-01)

RSU 129

1U, 9.5" deep universal rack shelf kit

(part #60-190-01)

MBU 125

under-desk mounting bracket kit

(part #70-077-01)

MBD 129

through-desk mounting bracket kit

(part #70-077-02)

Tabletop use

Four self-adhesive rubber feet are included with the unit. For
tabletop use, affix one foot at each corner of the bottom of the
DA, and place the unit in the desired location.

Rack mounting

UL rack mounting requirements

The following Underwriters Laboratories (UL) requirements
pertain to the safe installation of the equipment in a rack.

1

.

Elevated operating ambient temperature

— If the

equipment is installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack
environment may be greater than room ambient
temperature. Therefore, install the equipment in an
environment compatible with the maximum ambient
temperature (Tma = +113 °F, +45 °C) specified by Extron.

2

.

Reduced air flow

— Install the equipment in a rack so that

the amount of air flow required for safe operation of the
equipment is not compromised.

2-2