Optional blower installation instructions, Optional blowers – Empire Comfort Systems SR-18-3 User Manual

Page 23

Advertising
background image

16942-3-0506

Page 23

OPTIONAL BLOWER INSTALLATION INSTRUCTIONS

INSTALLING OPTIONAL BLOWER SRB-18 OR SRB-30

If heater is installed onto the wall, in order to install the optional blower,

the heater must be removed from the wall. If heater is installed on op-

tional floor stand there is adequate access area available to install the

optional blower.

1. Turn “OFF” gas supply to the heater.

2. Remove lower louver from casing assembly (2 screws).

3. Remove reflector from casing assembly (2 screws).

4. Remove upper louver from casing assembly (2 screws).

5. Remove on/off switch knockout from the casing assembly top.

6. Insert the on/off switch wires through the casing assembly top. The

on/off switch wires will enter the top portion of the casing assembly.

Snap on/off switch into the casing assembly top.

7. Route cord set through 9/16” (14mm) diameter hole on casing

assembly back. Insert approximately 3” (76mm) of cord set into

casing assembly back.

8. When you are facing the front of the heater, position the optional

blower assembly onto the top heat shield of the heater. The motor

wire harness should be facing into the top, right portion of the

heater.

9. Attach (1) pin terminal from black (hot) wire, smooth insulation on

cord set to (1) socket terminal from the on/off switch.

10. Attach (1) pin terminal from black (neutral) wire, ribbed insulation

on cord set to (1) socket terminal from white (neutral) wire on motor

wire harness.

11. Attach (1) pin terminal from the on/off switch to (1) socket terminal

from black (hot) wire on motor wire harness.

12. Attach the green ground wire from the motor wire harness and the

green ground wire from the cord set to the bottom right side of the

blower housing with (1) screw provided with the optional blower.

13. With the heater standing upright, position the air discharge opening

of the blower housing downward. Place the bottom flange of the

OPTIONAL BLOWERS

SRB-18 and SRB-30

for Unvented Room Heaters SR-18 and SR-30

Advertising