Sr-6 clearances – Empire Comfort Systems SR-18-3 User Manual

Page 8

Advertising
background image

16942-3-0506

Page 8

SR-6 CLEARANCES

Figure 3 (SR-6)

When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.

Left side 6 inches (152mm). Right side 6 inches 152mm).

Do not install in alcove or closet.

Rear wall 0 (0mm) inches. Ceiling 24 inches (610mm).

Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 10 inches (254mm).

Maximum horizontal extension of projection above the appliance 12 inches (305mm).

Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).

Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and proper operation must be provided.

Figure 4 (SR-6)

CEILING

WINDOW SILL OR SHELF

24” MIN

(610mm)

10” MIN

(254mm)

12” MAX

(305mm)

0” (0mm) CLEARANCE
TO REAR WALL

SIDE VIEW

2” MIN

(51mm)

FLOOR

Advertising