Page 9

Figure 5 (SR-10)

CEILING

WINDOW SILL OR SHELF

24” MIN

(610mm)

14” MIN

(356mm)

12” MAX

(305mm)

0” (0mm) CLEARANCE
TO REAR WALL

SIDE VIEW

2” MIN

(51mm)

FLOOR

Figure 6 (SR-10)

FLOOR

CEILING

SIDE WALL

24” MIN

(610mm)

14” MIN

(356mm)

6” MIN

(152mm)

6” MIN

(152mm)

2” MIN

(51mm)

SR-18 CLEARANCES

When facing the front of the appliance the following minimum

clearances to combustible construction must be maintained.

Left side 6 inches (152mm). Right side 6 inches (152mm).

Do not install in alcove or closet.

Rear wall 0 inches (0mm). Ceiling 36 inches (914mm).

Minimum vertical clearance from a projection above the

appliance (shelves, window sills, etc.) 36 inches (914mm).

Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).

Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and

proper operation must be provided.

FLOOR

2” MIN
(51mm)

6” (152mm)

MIN

6” (152mm)

MIN

SIDE WALL

CEILING

36” (914mm) MIN

Figure 7 (SR-18)

Advertising