Sr-30 clearances wall mount installation – Empire Comfort Systems SR-18-3 User Manual

Page 10

Advertising
background image

16942-3-0506

Page 10

When facing the front of the appliance the following

minimum clearances to combustible construction must be

maintained.

Left side 8 inches (203mm). Right side 8 inches

(203mm).

Do not install in alcove or closet.

Rear wall 0 inches (0mm). Ceiling 36 inches (914mm).

Minimum vertical clearance from a projection above

the appliance (shelves, window sills, etc.) 36 inches

(914mm).

Floor (top surface of carpeting, tile, etc.) 2 inches

(51mm).

Provide adequate clearances around air openings.

Adequate accessibility clearances for purposes of servicing

and proper operation must be provided.

Refer to Figures 9, 10, 11 and 12 for measurements in order to locate (4) mounting holes on wall. Figures 9, 10, 11 and 12 are the front
views of the heaters.

1. Remove lower louver from casing assembly (2 screws).

2. Remove reflector from casing assembly (2 screws).

3. Remove upper louver from casing assembly (2 screws).

SR-30 CLEARANCES

WALL MOUNT INSTALLATION