Icemaker, Fig. 17 – Hoshizaki KM-1900SAH/3 User Manual

Page 28

Advertising
background image

28

KM-1900SAH/3
KM-1900SRH/3

Bin Drain Outlet
3/4" FPT

Icemaker Water Supply Line Shut-Off Valve

Icemaker Water Supply Line Drain Valve

Icemaker Water Supply Inlet 1/2" FPT

Icemaker
Drain Outlet
3/4" FPT

Condensation
Drain Outlet
3/8" OD Hard
Tube

Bin

Icemaker

Remote Condenser Line Set Connections

Separate piping to approved drain.
Leave a 2 inch (5 cm) vertical air gap
between the end of each pipe and the
drain.

2-inch (5-cm)
air gap

Floor

Drain

Fig. 17

1. Icemaker
• Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" nominal

ID copper water tubing or equivalent is required for the icemaker water supply line.

• An icemaker water supply line shut-off valve and drain valve should be installed.
• Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" nominal ID hard pipe or equivalent

is required for the icemaker drain line. Condensation drain outlet is 3/8" OD hard tube.
The condensation drain line can be connected to the icemaker drain line or can be run
separately.

Minimum 3/8" Nominal
ID Copper Water Tubing

Minimum 3/4"
Nominal ID Hard Pipe

Vent Tube

Vent Tube