Electrical, Wiring color code, Electrical circuit identification – hussmann FMSS-L User Manual

Page 11: Electrical service receptacles (when applicable), Field wiring and serial plate amperage, Ballast location, User information, Stocking

Advertising
background image

rev. 0708

11

electrical

Wiring Color Code

CASE MUST BE GROUNDED

NOTE: Refer to label affixed to case to determine the actual

configuration as checked in the “TYPE INSTALLED”

boxes.

Electrical Circuit Identification

Standard lighting for all models will be full length fluorescent

lamps located on the front of the parent case. The switch

controlling the lights is located on the parent case.
electrical service receptacles (When applicable)

The receptacles located on the exterior of the merchandiser

are intended for scales and lighted displays. They are not

intended nor suitable for large motors or other external

appliances.

BEFORE SERVICING

ALWAYS DISCONNECT ELECTRICAL

POWER AT THE MAIN DISCONNECT

WHEN SERVICING OR REPLACING ANY

ELECTRICAL COMPONENT.

This includes (but not limited to) Fans, Heaters

Thermostats, and Lights.

field Wiring and serial Plate amperage

Field Wiring must be sized for component amperes printed

on the serial plate. Actual ampere draw may be less than

specified. Field wiring from the refrigeration control panel to

the merchandisers is required for refrigeration thermostats.

Case amperes are listed on the wiring diagram, but always

check the serial plate.
Ballast location

Ballasts are located within the access panel that runs the

length of the rear of the case. Refer to diagram on page 6.

User information

stocking

Improper temperature and lighting will cause serious

product loss. Discoloration, dehydration and spoilage

can be controlled with proper use of the equipment and

handling of product. Product temperature should always

be maintained at a constant and proper temperature.

This means that from the time the product is received,

through storage, preparation and display, the temperature

of the product must be controlled to maximize life of the

product. Hussmann cases were not designed to “heat up”

or “cool down” product - but rather to maintain an item’s

proper temperature for maximum shelf life. To achieve the

protection required always:

1. Minimize processing time to avoid damaging

temperature rise to the product. Product should be

at proper temperature.

. Keep the air in and around the case area free

of foreign gasses and fumes or food will rapidly

deteriorate.

3. Maintain the display merchandisers temperature

controls as outlined in the refrigerator section of this

manual.

4. Do not place any product into these refrigerators

until all controls have been adjusted and they

are operating at the proper temperature. Allow

merchandiser to operate a minimum of 6 hours

before stocking with any product.

5. When stocking, never allow the product to extend

beyond the recommended load limit.

air discharge

and return air flow must be unobstructed at all

times to provide proper refrigeration.

6. There are vents located at the base of the front of the

glass, just above the front rail. These vents supply a

continuous, gentle flow of air across the front glass

which inhibits condensation.

do not place any

signs or other restrictive objects on the front of

the refrigerator that will block these vents.

7. Keep the service doors closed (when applicable).

Refrigeration performance will be seriously affected

if left open for a prolonged period of time.