Cut and Plan views

FMSS

Front-Mount Self-Service case. Can be ordered to mount in front

of ANY service case. Base height can be modified to match any

service case bumper height.

ASC

PARENT CASE

FMSS

Height Modified to

match the ASC case

20"

“Field” Close Off

FMSS-L

Self-Service

Remote

(Self Contained)

Scale = 1"

16'' Remote

21

1

/

2

" S.C.

*26

3

/

8

"

*Dimensions

adjust at theses

points to match

service case

height

13

1

/

2

"

11

3

/

4

"

*10

1

/

2

"

6

1

/

8

"

26'' Remote

28

5

/

8

" S.C.

3

7

/

8

" Remote

8

7

/

8

" S.C.

Fan

4'

(VARIABLE LENGTHS)

3

1

/

2

"

4

1

/

2

"

12

1

/

2

"

24"

9

7

/

8

"

16"

(21

1

/

2

" S.C.

)

2

5

/

8

"

Ref. Drop In

Elec.

Drain

FMSS-L

Plan View

Scale = 1/2"

installation

location

The refrigerated merchandisers have been designed

for use only in air conditioned stores where temperature

and humidity are maintained at or below 75°F and 55%

relative humidity. DO NOT allow air conditioning, electric

fans, ovens, open doors or windows (etc.) to create air

currents around the merchandiser, as this will impair its

correct operation.
Product temperature should always be maintained at a

constant and proper temperature. This means that from the

time the product is received, through storage, preparation

and display, the temperature of the product must be

controlled to maximize life of the product.
Uncrating the stand

Place the fixture as close to its permanent position as

possible. Remove the top of the crate. Detach the walls

from each other and remove from the skid. Unbolt the case

from the skid. The fixture can now be lifted off the crate

skid.

lift only at base of stand!

exterior loading

These models have

not been structurally designed to

support excessive external loading.

do not walk on their

tops; This could cause serious personal injury and damage

to the fixture.
setting and Joining

The case that the FMSS-L connects to (the parent case)

through the rear of the case must be leveled and set prior to

installing the FMSS-L. The sectional construction of these

models enable them to be joined in line - to give the effect of

one continuous display. A joint Trim Kit is supplied with each

case line to cosmetically “mask” the sectional joints.
leveling

iMPortant! it is iMPerative that Cases Be

leveled froM front to BaCK and side to side

Prior to Joining. a level Case is neCessarY

to insUre ProPer oPeration, Water drainage,

glass alignMent, and oPeration of the hinges

sUPPorting the glass. leveling the Case

CorreCtlY Will solve Most hinge oPeration

ProBleMs.