Operation, Low voltage adjustment (smart guns only), Table 3: low voltage adjustment – haier PRO XS3 309292L User Manual

Page 15

Advertising
background image

Operation

309292L

15

Operation

Low Voltage Adjustment (Smart
Guns Only)

The ES HI/LO switch enables you to switch between full
voltage and a lower voltage output. The lower voltage is
factory set, but can be adjusted.

1.

Set the ES HI/LO switch to LO.

2.

Remove the LO VOLTAGE adjustment plug (53). Set
the desired voltage, using a small screwdriver to
slide switches 1 and 2 ON or OFF, according to
Table 3 . Also see F

IG

. 5.

Fig. 5. Low Voltage Adjustment Switches

INSTRUCTIONS

Refer to the gun operation manual (supplied)
for Setup, Shutdown, and Daily Care proce-
dures.

100

%

KV

μα

0

ti1529a

53

1

2

ON

OFF

Table 3: Low Voltage Adjustment

60 kV Guns

85 kV Guns

1

2

kV

1

2

kV

ON

ON

50

ON

ON

70

ON

OFF

40

ON

OFF

60

OFF

ON

35

OFF

ON

50

OFF

OFF

30

OFF

OFF

40

Factory
Setting

Advertising