Installation, Ventilate the spray booth o, Warning – haier PRO XS3 309292L User Manual

Page 7: Install the system, Warning sign, Ventilate the spray booth

Advertising
background image

Installation

309292L

7

Installation

Install the System

F

IG

. 2. shows a typical electrostatic air spray system. It

is not an actual system design. For assistance in
designing a system to suit your particular needs, contact
your Graco distributor.

Warning Sign

Mount warning signs in the spray area where they can
easily be seen and read by all operators. An English
Warning Sign is provided with the gun.

Ventilate the Spray Booth

Electrically interlock the gun air supply with the ventila-
tors to prevent gun operation without ventilating fans
operating. Check and follow all National, State, and
Local codes regarding air exhaust velocity require-
ments.

High velocity air exhaust will decrease the operating effi-
ciency of the electrostatic system. Air exhaust velocity of
100 ft/min (31 linear meters/minute) should be sufficient.

WARNING

Fire, Explosion, and Electric Shock Hazard

Installing and servicing this equipment
requires access to parts which may cause
electric shock or other serious injury if work
is not performed properly.

Do not install or service this equipment

unless you are trained and qualified.

Be sure your installation complies with

National, State and Local codes for the
installation of electrical apparatus in a
Class I, Group D or a Class II 2G Haz-
ardous Location.

Comply with all applicable local, state,

and national fire, electrical, and other
safety regulations.

WARNING

Flammable or Toxic Vapor Hazard

Provide fresh air ventilation to avoid the
buildup of flammable or toxic vapors when
spraying, flushing, or cleaning the gun. Do
not operate the gun unless ventilation fans
are operating.

Advertising