Installation

8

309292L

Fig. 2. Typical Installation

Key

I O

ES

ti1498a

A

B*

C*

D

*E

F

G

H

J*

K

L

M

N

O

P

Q*

*R

S

T

U*

V

W

C

G

ES ON/OFF valve: I is ON, 0 is OFF

The air supply to the
gun must be electri-
cally interlocked with
the ventilators to pre-
vent the power supply
from operating without
ventilating fans on.

Non-Hazardous Area

Hazardous Area

A

Main Air Supply Line

B*

Ventilation Fan Interlock Solenoid Valve

C*

Main Air Supply Shutoff Valve (bleed-type)

D

Pump Air Line Filter/Water Separator

E*

Pump Air Supply Shutoff Valve (bleed-type)

F

Air Line Lubricator

G

Air Pressure Regulator

H

Pump

J*

Pump Ground Wire

K

Fluid Filter

L

Fluid Supply Line Shutoff Valve

M

Fluid Pressure Regulator

N

Fluid Supply Line

O

Gun Air Line Filter/Water Separator

P

Gun Air Supply Line Shutoff Valve

Q*

Air Hose Ground Wire

R*

Graco Grounded Air Hose

S

Electrostatic Air Spray Gun

T

Air Line Drain Valve

U*

Fluid Drain Valve

V

Gun Air Inlet

W

Gun Fluid Inlet

*

Required for safe operation. Must be purchased

separately. NOTE: Solenoid valve (B) is not

offered as a Graco accessory.