Set the ventilation mode parameters – Honeywell HVC0001 User Manual

Page 8

Advertising
background image

Owner’s Guide 400-305-000-EFS

6

ENG

LISH

At first power-up, you will be prompted to set the following parameters:

Set the Ventilation Mode parameters

Select Units
(US /Metric)

Set Fan Capacity ***
(CFM or LPS)

ASHRAE 62.2
Pass/Fail ****

Set Floor Size **
(Sq. ft or Sq. M)

Set no. of
Bedrooms *

Normal
Display

*

No. of bedrooms (1, 2, ..., 6)

**

Floor space (1000, 1100, ..., 5000 sq. ft. or 100, 110, ..., 500 m

2

)

*** Fan capacity (30, 40, ..., 200 CFM or 15, 20, ..., 100 LPS)
**** The controller shows whether you pass or fail ASHRAE

Standard 62.2 for ventilation and the percentage of time the fan
will run every hour. If the controller indicates Fail; this usually
means the fan capacity is insufficient for your house.

If you press the main button for 3 seconds or do
not press any button for 60 seconds, the
controller will go to normal display. If the
parameters are not set, you will again be
prompted the next time the controller is powered
up, for example, after a power outage. The
parameters can be set at any time (see page 10).

400-305-000-B (69-2316EFS-03).book Page 6 Monday, September 28, 2009 11:06 AM