Table 13, Flange description – Honeywell ST 3000 User Manual

Page 47

Advertising
background image

4.2

Piping ST 3000 Transmitter,

Continued

Flange descriptions

Table 13 describes the available flange connections for flange mounted
liquid level transmitters.

Table 13 Flange Description

Transmitter Type

Description

Flush or Extended
Diaphragm

2-inch 150# serrated–face flange with 4 holes 19 mm (3/4 in) diameter on 120.7
mm (4.75 in) diameter bolt circle and an outside diameter of 150 mm (5.91 in).

2-inch 150# serrated–face flange with 8 holes 19 mm (3/4 in) diameter on 127 mm
(5.00 in) diameter bolt circle and an outside diameter of 165 mm (6.50 in).

3-inch 150# serrated–face flange with 4 holes 19 mm (3/4 in) diameter on 152.4
mm (6.00 in) diameter bolt circle and an outside diameter of 190 mm (7.48 in).

3-inch 300# serrated–face flange with 8 holes 22.2 mm (7/8 in) diameter on 168.3
mm (6.62 in) diameter bolt circle and an outside diameter of 210 mm (8.27 in).

4-inch 150# serrated–face flange with 4 holes 19 mm (3/4 in) diameter on 190.5
mm (7.50 in) diameter bolt circle and an outside diameter of 230 mm (9.05 in).

4-inch 300# serrated–face flange with 8 holes 22.2 mm (7/8 in) diameter on 255
mm (10.04 in) diameter bolt circle and an outside diameter of 200 mm (7.87 in).

DN 50 PN 40 serrated–face flange with 4 holes 18 mm (0.71 in) diameter on 125
mm (4.92 in) diameter bolt circle and an outside diameter of 165 mm (6.50 in).

DN 80 PN 40 serrated–face flange with 8 holes 18 mm (0.71 in) diameter on 160
mm (6.30 in) diameter bolt circle and an outside diameter of 200 mm (7.87 in).

DN 100 PN 40 serrated–face flange with 8 holes 22 mm (0.87 in) diameter on 190
mm (7.48 in) diameter bolt circle and an outside diameter of 235 mm (9.25 in).

Pseudo Flange Head 2-inch, 150 lbs serrated-face flange with 4 holes 15.9 mm (5/8 in) diameter on

120.6 mm (4-3/4 in) diameter bolt circle and an outside diameter of 152.4 mm (6
in).

3-inch, 150 lbs serrated-face flange with 4 holes 19 mm (3/4 in) diameter on 152
mm (6 in) diameter bolt circle and an outside diameter of 190 mm (7-1/2 in).

Flush Mount

Gauge STG93P

25.4 mm (1-inch) pipe mount. (316L SS standard option.)

General piping
guidelines

• When measuring fluids containing suspended solids, install permanent

valves at regular intervals to blow-down piping.

• Blow-down all lines on new installations with compressed air or steam

and flush them with process fluids (where possible) before connecting
these lines to the transmitter’s meter body.

• Be sure all the valves in the blow-down lines are closed tight after the

initial blow-down procedure and each maintenance procedure after
that.

Continued on next page

2/05

ST 3000 Release 300 Installation Guide

37

Advertising