Configuring Smart Meter Using Pushbuttons,

Continued

Setting Lower Display
Values,
continued

Table A-7

Setting Lower Display Values for Smart Meter Display, continued

Step Action

Meter

Display

3

Press Increase button to call up next

available magnitude range selection or

Decrease button to call up previous

magnitude range selection.

NOTE: This action enables the multiplier (K)

for indicating larger ranges and shifts

the decimal point of the digital display

left or right depending on which button

is pushed.

The display shows largest

positive number for given range

selection so you can select a range

that is just larger than the

range to be

set for best display precision.

Hold

respective key to scroll forward or

backward through the selections.

Repeat this action until desired selection is on

display.

Magnitude range selections.

%

100

0

ANALOG

UPPER

VALUE

UNITS

LOWER

VALUE

S E T

VAR

SEL.

19 . 9

9

19.99
199.9
1999
19.99K*
199.9K*
1999K*
19990K*

Press and hold to
scroll forward
through selections

Press and hold to
scroll backward
through selections

*The "K" multiplier
indicator appears
below the digital
reading on the display.

4

Press LOWER VALUE button to initiate lower

value setting.

Readout goes blank except for first active digit

which will be 0 unless lower value was set

before.

%

100

0

ANALOG

UPPER

VALUE

UNITS

LOWER

VALUE

S E T

VAR

SEL.

0