30

F-801MWH

We reserve the right to make changes in specifications and design without prior notice.

APPROXIMATE

Ambient

Water Temp. (F)

ICE PRODUCTION

Temp. (F)

PER 24 HR.

70

* 720

(327)

693

(315)

677

(307)

80

661

(300)

646

(293)

630

(286)

90

616

(279) * 605

(274)

587

(266)

lbs./day ( kg/day)

100

573

(260)

560

(254) * 520

(236)

APPROXIMATE ELECTRIC

70

* 1076

--

1076

--

1076

--

CONSUMPTION

80

1076

--

1077

--

1077

--

90

1077

--

* 1078

--

1076

--

watts

100

1074

--

1071

--

* 1069

--

APPROXIMATE WATER

70

* 306

(1158)

397

(1504)

631

(2387)

CONSUMPTION PER 24 HR.

80

318

(1205)

415

(1571)

666

(2520)

(TOTAL)

90

331

(1251) * 433

(1638)

704

(2666)

gal. / day (l/day)

100

344

(1304)

457

(1728) * 778

(2944)

EVAPORATOR OUTLET TEMP.

70

*

17

(-8)

17

(-8)

18

(-8)

°F (°C)

80

19

(-7)

19

(-7)

20

(-7)

90

20

(-7)

*

20

(-7)

20

(-7)

100

20

(-7)

20

(-7)

*

21

(-6)

HEAD PRESSURE

70

* 265

(18.6)

265

(18.6)

266

(18.7)

80

265

(18.6)

265

(18.6)

266

(18.7)

90

265

(18.6) * 265

(18.6)

266

(18.7)

PSIG (kg/cm

2

G)

100

265

(18.6)

265

(18.6) * 266

(18.7)

SUCTION PRESSURE

70

*

42

(3.0)

43

(3.0)

44

(3.1)

PSIG (kg/cm

2

G)

80

42

(3.0)

43

(3.0)

44

(3.1)

90

42

(3.0) *

43

(3.0)

44

(3.1)

100

42

(3.0)

43

(3.0) *

44

(3.1)

Note: The data without *marks should be used for reference.

HEAT OF REJECTION FROM COMPRESSOR

1050 BTU/h (AT 90°F / WT 70°F)

WATER FLOW FOR CONDENSER

15 gal/h (AT 90°F / WT 70°F)

PRESSURE DROP OF COOLING WATER LINE

Less than 7 PSIG

HEAT OF REJECTION FROM CONDENSER

50

70

90

5155 BTU/h (AT 90°F / WT 70°F)