10. Removal and Replacement of Flush Water Valve

1) Turn off the power supply, remove the panels and close the water supply line shut-off

valve.

2) Remove the clamp and disconnect the hose from the flush water valve.

Note: Water may still remain inside the evaporator. Be sure to drain the water into the

drain pan.

3) Disconnect the terminals from the flush water valve.

4) Remove the flush water valve from the bracket.

5) Remove the drain pipe from the flush water valve.

6) Connect the drain pipe to the new flush water valve, and place the valve in position.

7) Connect the hose to the flush water valve and secure it with the clamp.

8) Pour water into the reservoir, and check for water leaks on the flush water valve.

9) Open the water supply line shut-off valve, and turn on the power supply.

10) Move the flush switch to the "ICE" position.

11) Check for water leaks.

12) Move the flush switch to the "FLUSH" position, and make sure water is flushing.

13) Move the flush switch to the "ICE" position.

14) Replace the panels in their correct position.