F-801MWH-C

We reserve the right to make changes in specifications and design without prior notice.

AC SUPPLY VOLTAGE

115/60/1

COMPRESSOR

120 V

8.5 RLA

51 LRA

GEAR MOTOR

120 V

3 FLA

1/4 HP

OTHER

120 V

0.03 A

MAXIMUM FUSE SIZE

20 A

MAX. HACR BREAKER (USA ONLY)

20 A

MAX. CIRC. BREAKER (CANADA ONLY)

20 A

MINIMUM CIRCUIT AMPACITY

20 A

APPROXIMATE ICE PRODUCTION

Ambient

PER 24 HR.

Temp.(°F)

lbs./day ( kg/day )

70

* 645 (293)

620 (281)

608 (276)

Reference without *marks

80

596 (270)

585 (265)

574 (260)

90

563 (255) * 550 (249)

541 (246)

100

531 (241)

521 (236) * 485 (220)

SHAPE OF ICE

Cubelet

ICE QUALITY

Approx. 80%, Ice (90/70°F, Conductivity 200 µs/cm)

APPROXIMATE STORAGE CAPACITY

N/A

ELECTRIC & WATER CONSUMPTION

90/70°F

70/50°F

ELECTRIC W (kWH/100 lbs.)

1075 (4.7)

1083 (4.1)

POTABLE WATER

66 (12)

77 (12)

WATER-COOLED CONDENSER

302 (55)

199 (31)

gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH)

22" x 27-3/8" x 25-15/16" (560 x 695 x 658mm)

EXTERIOR FINISH

Stainless Steel, Galvanized Steel (Rear)

WEIGHT

Net 176 lbs. ( 80 kg ), Shipping 207 lbs. ( 94 kg )

CONNECTIONS - ELECTRIC

Permanent - Connection

- WATER SUPPLY

Inlet 1/2" FPT

Cond. Inlet 1/2" FPT

- DRAIN

Outlet 3/4" FPT

Cond. Outlet 3/8" FPT

ICE MAKING SYSTEM

Auger type

HARVESTING SYSTEM

Direct Driven Auger ( 1/4HP Gear Motor )

ICE MAKING WATER CONTROL

Float Switch

COOLING WATER CONTROL

N/A

BIN CONTROL SYSTEM

Mechanical Bin Control ( Proximity Sw. )

COMPRESSOR

Hermetic, Model RS43-C2E-CAA

CONDENSER

Water-cooled, tube in tube type

EVAPORATOR

Copper Tube on Cylinder

REFRIGERANT CONTROL

Thermostatic Expansion Valve

REFRIGERANT CHARGE

R-404A,

(470 g)

DESIGN PRESSURE

High 427 PSIG, Low 230 PSIG

PC BOARD CIRCUIT PROTECTION

High Voltage Cut-off Relay

COMPRESSOR PROTECTION

Auto-reset Overload Protector

GEAR MOTOR PROTECTION

Fuse (3A)

REFRIGERANT CIRCUIT PROTECTION

Auto-reset High Pressure Control Switch

LOW WATER PROTECTION

Float Switch and Timer

ACCESSORIES - SUPPLIED

Spare Fuse

- REQUIRED

Ice Storage Bin

OPERATING CONDITIONS

VOLTAGE RANGE

104 - 127 V

AMBIENT TEMP.

45 - 100° F

WATER SUPPLY TEMP.

45 - 90° F

WATER SUPPLY PRESSURE

10 - 113 PSIG

1lb 1oz

50

WATER TEMP. (°F)

70

90