Honeywell STR12D User Manual

Page 27

Advertising
background image

34-ST-03-64

Page

27

STR14A

STR12D & 13D

14G & 17G

TABLE III - OPTIONS

e

e

e

e

e

e

r

r

r

ME

SM

CI

f

f

f

ZS

m

m

LZ

x

x

NE

15 15 15
14 14 14

LP

CC

15 15 15
21 21 21

WP

WX

SH

n

n

n

A1

n

n

n

A2

u

u

u

TB

a

a

a

a

a

a

a

a

a

a

a

a

CR

SS

B7

G1

j

j

j

G2

j

N1

j

j

j

N2

j

MB

SB

FB

Users Manual Paper Copy (Standard, HC/H6 or FF ships accordingly)

0X

h

h

h

TP

F1

F3

F5

F6

22 22 22

F7

o

o

F8

16

MT

2

2

2

FE

SP

TG

i

i

Stainless Steel Customer Wired-On Tag
(4 lines, 28 characters per line, customer supplied information)

1/2" NPT to 3/4" NPT 316 SS Conduit Adapter

Adapter (use for FM and CSA Approvals)

FC

A3

H6

Communication Options (Must choose a communications option)

SL

FF

NAMUR Failsafe Software

HC

Lightning Protection

Transmitter Configuration - (Fieldbus)

SIL 2 - TÜV Certified transmitter (requires HC or H6 and WP options)

PG

TL

Transmitter Configuration - (non-Fieldbus)

GE

UM

TC

Write Protection (Delivered in the "enabled" position)
Write Protection (Delivered in the "disabled" position)

Marine Type Approvals (DNV, ABS, BV, KR & LR)

b

NACE Certificate (F0198) for all welded meter bodies only

Teflon Coated Seal Diaphragm (1 Seal) - only for anti-sticking

NACE Certificate (Process-Wetted only) (FC33338)

b

b

i

b

Meter Body Options

(Seal bolt material depends on Transmitter bolt material)

A286 SS (NACE) Bolts and 304 SS (NACE) Nuts for Heads

NACE Certificate (Process-Wetted & Non-Process Wetted) (FC33339)

Certificate of Conformance (F3391)

B7M Bolts and Nuts for Process Heads

Gold Plated Seal Diaphragm (1 Seal)

Teflon Coated Seal Diaphragms(2 Seals) - only for anti-sticking

Transmitter Mounting Brackets Options

Custom Calibration and I.D. in Memory

Local Zero & Span

HART 5.x Protocol compatible electronics

Custom Configuration of Smart Meter

Indicating Meter Options

HART 6.x Protocol compatible electronics

316 SS Electronics Housing - with M20 Conduit Connections
1/2" NPT to M20 316 SS Conduit Adapter (BASEEFA EEx d IIC)

Transmitter Housing & Electronics Options

Smart Meter

Analog Meter (0-100 Even 0-10 Square Root)

SIL Certificate (SIL 2/3) (FC33337)

Clean Transmitter for Oxygen or Chlorine Service with Certificate

Flat Mounting Bracket

Certificate of Origin (F0195)

316 SS Bolts and 316 SS Nuts for Process Heads

Stainless Steel Housing with M20 to 1/2" NPT 316 SS Conduit

b

Over-Pressure Leak Test with F3392 Certificate

Stainless Steel Customer Wired-On Tag (blank)

End Cap Live Circuit Warning Label in Portuguese (only with ATEX 3D)

End Cap Live Circuit Warning Label in Spanish (only with ATEX 3D)

Gold Plated Seal Diaphragm (2 Seals)

Mounting Bracket - 304 SS

Remote Seal Options

End Cap Live Circuit Warning Label in Italian (only with ATEX 3D)
End Cap Live Circuit Warning Label in German (only with ATEX 3D)

FOUNDATION Fieldbus Communications

Local Zero

Calibration Test Report and Certificate of Conformance (F3399)

FG

Analog only (can be configured using appropriate Honeywell DE tool)

AN

DE Protocol communications

DE

b

Services/Certificates Options

FMEDA Certificate (SIL 1) (FC33321)

b

Mounting Bracket - Carbon Steel

b

b

b

b

b

b

Advertising