Troubleshooting guide

Problem

Cause

Remedy

Low tractive force

Fault in boost or high-pressure system Check suction filter in return line

Check boost pressure in hydraulic system

Check high-pressure hydraulic system

Check for leaks on variable-
displacement pumps and wheel motors

Check control units and proportional
solenoids of variable-displacement
pumps

Check maximum current at
proportional solenoids

Eliminate detected faults

No forward and reverse travel

Drive of variable-displacement pumps
defective

Forward/reverse selector switch in
neutral

Machine started with preselected
direction of travel

No power supplied to the electronics

Electrical connection to the variable
pump interrupted

Repair

Put forward/reverse selector switch
in desired direction of travel

Put forward/reverse selector switch
in neutral and preselect desired
direction of travel

Check fuses
Check electric connection

Make connection