Check the air cleaner system, C 4.74, Operating instructions – Holder C-Trac 4.74 User Manual

Page 166: Maintenance as required

Advertising
background image

Operating instructions

149 443

165

C 4.74

Maintenance as required

1

2

Bild_C242

3

2

4

Bild_C243

Check the air cleaner system

The filter cartridge must be serviced when the flow resist-
ance of the filter is highest due to the restriction of the ele-
ment. This is indicated by the sounding of an alarm.
-

Stop the engine.

-

Raise the dump body (loading platform*) and secure it
against accidental lowering.

-

Remove the clamping band (1) from the air cleaner
housing and turn the air cleaner housing up.

-

Open the air cleaner cover clips (2).

-

Pull off the housing cover and clean the dust ejection
valve (4).

-

Pull the air filter element (3) out of the housing by
rotating it slightly.

Cleaning:
-

Blow out the filter element from the inside with com-
pressed air having a pressure of maximum of 5 bar.

Replacement:
-

Install a new filter element.

Clean the air cleaner housing with a moist cloth before in-
stallation.
The installation of the air filter element is performed in the
reverse order.

* Option

Advertising