Check the battery and cable terminals, Check the high pressure hoses, C 4.74 – Holder C-Trac 4.74 User Manual

Page 169: Operating instructions, Maintenance every 125 hours

Advertising
background image

C 4.74

Operating instructions

168

149 443

Maintenance every 125 hours

1

Bild_C246

Check the battery and cable terminals

CAUTION
When working on the electrical equipment,
always disconnect the ground lead (1) at the
battery.

-

Check the battery acid level and inspect the battery
for leaks. Observe the information of the battery
manufacturer.

-

Remove any corrosion on the battery terminals.

-

Grease the battery terminals with non-acidic battery
grease.

-

Check cables and cable ends for secure connection
and damage.

-

Replace any damaged cables and terminals.

Check the high pressure hoses

-

Check the high pressure hoses for cracks, bending
and chafing, and for porous surfaces.
Replace damaged high-pressure hoses immediately.

This work may only be carried out by an authorized work-
shop.