Main burner flame check – Honeywell PGF3 User Manual

Page 7

Advertising
background image

-- 7 --

462 06 1211 00

3/17/06

Pilot Burner Flame Check (All models

except PGF3, PGX3, and PDX3)

Adjust flames so they surround

3

/

8

″ (9 mm) to

1

/

2

″ (13 mm) of the

sensor tip (See Figure 11).

1. Remove the cap from the pilot adjusting screw (See Fig-

ures 7 & 8).

2. Turn pilot adjusting screw counterclockwise to increase,

clockwise to decrease.

3. Replace the cap on the pilot adjusting screw.

Pilot Burner (HSP)

10--11--65

Sensor Tip

Proper Flame

Adjustment

Hot Surface

Igniter

Figure 11

Main Burner Flame Check

Check for the following:

D

Stable and blue flames (See Figure 12). Dust may cause

orange tips or wisps of yellow, but flames MUST NOT have

solid, yellow tips.

D

Flames extending directly from burner into heat exchanger.

D

Flames DO NOT touch sides of heat exchanger

Main Burner

BLUE FLAME

25--00--07a

Figure 12

Advertising