Pci riser cage led – HP DL385 User Manual

Page 22

Advertising
background image

Server component identification 22

Online/activity LED

(green)

Fault/UID LED

(amber/blue)

Interpretation

Flashing regularly

(1 Hz)

Amber, flashing

regularly (1 Hz)

Do not remove the drive. Removing a drive may

terminate the current operation and cause data loss.
The drive is part of an array that is undergoing capacity

expansion or stripe migration, but a predictive failure alert has

been received for this drive. To minimize the risk of data loss, do

not replace the drive until the expansion or migration is

complete.

Flashing regularly

(1 Hz)

Off

Do not remove the drive. Removing a drive may

terminate the current operation and cause data loss.
The drive is rebuilding, or it is part of an array that is undergoing

capacity expansion or stripe migration.

Flashing irregularly Amber, flashing

regularly (1 Hz)

The drive is active, but a predictive failure alert has been

received for this drive. Replace the drive as soon as possible.

Flashing irregularly Off

The drive is active, and it is operating normally.

Off Steadily

amber

A critical fault condition has been identified for this drive, and

the controller has placed it offline. Replace the drive as soon as

possible.

Off

Amber, flashing

regularly (1 Hz)

A predictive failure alert has been received for this drive.

Replace the drive as soon as possible.

Off Off The drive is offline, a spare, or not configured as part of an

array.

PCI riser cage LED

CAUTION: To prevent damage to the server or expansion boards, power down the server and remove all

AC power cords before removing or installing the expansion boards.

Status
On = AC power connected
Off = AC power disconnected

Advertising