Honeywell CHRONOTERM IV T8624D User Manual

T8624d chronotherm, Iv deluxe zone multistage thermostat, Recycling notice

Advertising
background image

X-XX UL

INSTALLATION INSTRUCTIONS

®U.S. Registered Trademark
Copyright © 1997 Honeywell Inc. • • All Rights Reserved

T8624D Chronotherm

®

IV

Deluxe Zone

Multistage Thermostat

APPLICATION

The T8624D Chronotherm® IV Deluxe ZoneMultistage
Thermostat provides electronic control of 24 Vac
multistage zoned heating and cooling system. Refer to

Table 1 for a general description of the thermostat.
The T8624 thermostat requires a common wire to
supply power.

Table 1. Description of T8624 Thermostats.

RECYCLING NOTICE

If this control is replacing a control that contains
mercury in a sealed tube, do not place your old
control in the trash.

Contact your local waste management authority for
instructions regarding recycling and the proper
disposal of the old thermostat.

INSTALLATION

When Installing this Product...

1. Read these instructions carefully. Failure to follow

the instructions can damage the product or cause a
hazardous condition.

2. Check the ratings given in the instructions and on

the product to make sure the product is suitable for
your application.

3. Installer must be a trained, experienced service

technician.

4. After completing installation, use these instructions

to check out the product operation.

Location

Install the thermostat about 5 ft (1.5m) above the floor in
an area with good air circulation at average temperature.
See Fig. 1.

Do not install the thermostat where it can be affected by:

drafts, or dead spots behind doors and in corners.

hot or cold air from ducts.

radiant heat from sun or appliances.

concealed pipes and chimneys.

unheated (uncooled) areas such as an outside wall
behind the thermostat.

Wallplate Installation

The thermostat can be mounted horizontally on the wall or
on a 2 in. x 4 in. wiring box. Position wallplate horizontally
on the wall or on a 2 in. x 4 in. wiring box.

³

Position and level the wallplate (for appearance
only). The thermostat will function properly even
when not level.

Model

Application

Powering Method

Changeover

System Selection

Fan Selection

T8624D

Zone 1 on MABS II or
TotalZone® system

Requires common wire
to power supply

Automatic or

manual

Heat-Off-Cool-Auto

On-Auto

69-1074

Advertising