Honeywell ADEMCO 5817 User Manual

Page 2

Advertising
background image

— 2 —

— 3 —

3. If concealed wiring is to be used, feed the wires through the concealed wiring entry hole at

one corner of the plate (surface wiring is mentioned in Step 5 below).

4. Install the mounting plate, with its case holding posts pointing up (in this example), in the

location selected as described in the control unit’s installation instructions. Use the flat-head
screws supplied.

5. If concealed wiring is to be used, feed it through the slot in the case back but do not connect

to the terminal block yet. Surface wiring should enter via the thin "breakout" area provided in
the case wall.

6. Attach the case back to the mounting plate by sliding the keyhole slots in the case back down

onto the mounting plate’s hooks. The locking tab will click as the case back locks in place.

7 Set the DIP switch (after the control has enrolled the transmitter’s input IDs) for the desired

primary loop characteristics, as described in the table below.

P R I M A R Y L O O P O P T I O N S T A B L E

SWITCH

D I P S W I T C H P O S I T I O N

SETTING 1

2

3

4

ON

REPEATING

TRANSMISSION

(every 4 sec.)

UPON PRIMARY

LOOP FAULT

Use for high-priority

alarm, such as fire.

NORMALLY

OPEN CIRCUIT

PRIMARY LOOP

SLOW

PRIMARY LOOP

RESPONSE

(Approx. 200mSec

Normally Closed
Response Time)

3 MINUTE, ALL LOOP

TRANSMISSION INHIBIT

AFTER RESTORE OF

PRIMARY LOOP

See Note c.

This affects the Aux. loops as

well. Use on frequently used

doors, etc. to conserve battery.

OFF

SINGLE

TRANSMISSION

PER PRIMARY

LOOP

CHANGE-OF-

STATE

NORMALLY

CLOSED

CIRCUIT

PRIMARY

LOOP

FAST

PRIMARY LOOP

RESPONSE

(Approx. 5mSec

Normally Closed
Response Time)

NO

TRANSMISSION

INHIBIT

Notes: a. While the transmitter is being enrolled by the control, all DIP switch positions should

be OFF.

b. Except in the case of the position 4 ON setting, the Auxiliary loops are not affected by

the DIP switch settings.

c.

For UL installations with fire zones, the position 4 ON setting must not be used.

WIRING CONNECTIONS

With the battery still not inserted, connect the loop wiring to the unit’s terminals (see Diagram 2).
Note: If a contact loop is not to be used, no connection is needed across its terminals.

BATTERY INSTALLATION/REPLACEMENT

1. Remove the transmitter’s cover (if not already off) as described in Mounting Step 1.
2. Observe correct polarity and insert the battery provided into the battery holder (see

Diagram 2). Take care not to bend the antenna.
Note: Replace

battery

only with: Duracelll DL123A, Sanyo CR123A,

Panasonic CR123A, ADEMCO 466, or Varta CR123A.

CAUTION: Risk of fire, explosion, and burns. Do not recharge, disassemble, heat above

212°F (100°C), or incinerate. Dispose of used batteries promptly. Keep away
from children.

3. To replace the cover, engage the hooks along one edge and snap shut.

SPECIFICATIONS

Dimensions

1-9/16"W x 3-1/2"H x 1-3/16"D (40mm x 89mm x 30mm)

Battery

3V Lithium (see BATTERY INSTALLATION/REPLACEMENT).

TO THE INSTALLER

Regular maintenance and inspection (at least annually) by the installer and frequent testing by
the user are vital to continuous satisfactory operation of any alarm system.
The installer should assume the responsibility of developing and offering a regular maintenance
program to the user, as well as acquainting the user with the proper operation and limitations of
the alarm system and its component parts. Recommendations must be included for a specific
program of frequent testing (at least weekly) to ensure the system’s operation at all times.

REFER TO THE CONTROL'S

INSTALLATION INSTRUCTIONS FOR THE

RECEIVER/CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS ON
LIMITATIONS OF THE ENTIRE ALARM SYSTEM.

CASE

HOLDING

POSTS (2)

PLATE

MOUNTING

HOLES (2)

ALIGNMENT GUIDE STRIP
(NOT USED IN THIS APPLICATION.
BREAK AWAY, IF DESIRED.)

CONCEALED WIRING
ENTRY HOLE

CASE LOCKING TAB

Diagram 1: MOUNTING PLATE


Diagram 2: 5817 (SHOWN WITH COVER REMOVED)