Service, Replacing fan motors and blades, Rl / rm / rln / rmn / rlni /rlnie – hussmann P/N 0387183_D User Manual

Page 29: Warning

Advertising
background image

REPLACING FAN MOTORS AND BLADES

See cross section for location of evaporator
fans. Should it ever be necessary to service or
replace the fan motors or blades be certain that
the fan blades are re-installed correctly.

For access to RL / RM / RLN / RMN / RLNI /

RLNIE fans:

1. Turn off power.

2. Remove bottom display pans.

3. Disconnect fan from wiring harness.

4. Remove fan blade.

5. Remove screws holding fan motor/bracket

assembly to plenum and remove assembly.

6. Replace fan motor/bracket assembly and

reinstall screws.

7. Reinstall fan blade.

8. Reconnect fan to wiring harness.

9. Turn on power.

10. Verify that motor is working and blade is

turning in the correct direction.

11. Close air gaps under fan plenum. Warmer air

moving into refrigerated air reduces effective
cooling. If the plenum does not rest against
the case bottom without gaps, apply foam
tape to the bottom of the fan plenum to
reduce improper air movement. Use silicone
sealant to close other gaps.

12. Replace display pans. Bring merchandiser to

operating temperature before restocking.

Reach-In

P/N 0387183_D

6-1

HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.

Always disconnect the electrical power at
the main disconnect when servicing or
replacing any electrical component. This
includes, but is not limited to, such items
as fans, heaters, thermostats and lights.

WARNING

!

SERVICE

Airflow

Direction

S

er

vi c e #

M O . X

X X XX X X

XX XXXXX

Screws

Plenum

Fan Assembly

Fan Blade

Motor

Bracket

Speed-Nut

Hussmann recommends against frame heater
cycling with

Innovator

doors to prevent door

seals from freezing to the frames and tearing.

Advertising