1. Turn off power.

2. Remove bottom display pans.

3. Disconnect fan from wiring harness.

4. Remove fan blade.

5. Lift fan plenum and remove screws holding

bottom of motor to fan basket.

6. Replace fan motor and blade.

7. Lower fan plenum.

8. Reconnect fan to wiring harness.

9. Turn on power.

10. Verify that motor is working and blade is

turning in the correct direction.

11. Close air gaps under fan plenum. Warmer air

moving into refrigerated air reduces effective
cooling. If the plenum does not rest against
the case bottom without gaps, apply foam
tape to the bottom of the fan plenum to
reduce improper air movement. Use silicone
sealant to close other gaps.

12. Replace display pans. Bring merchandiser to