Hearth and Home Technologies SIMPLIFYRE SFE-35 User Manual

Page 4

Advertising
background image

4

Hearth & Home Technologies Inc. • SFE-35 • 4050-313 Rev C • 01/08

A Unpacking the Unit

Carefully remove packaging from the unit. The front screen

is held in place with four Phillips head screws. To remove

the screen, extract the screws. Grasp the screen frame and

pull out.

B. Locating Your Electric Fireplace

Your new electric fi replace may be installed virtually

anywhere in your home. However, when choosing a location

ensure that the general instructions are followed. For best

results, install out of direct sunlight.
Power supply service must be either completed or placed

within the heater prior to fi nishing to avoid reconstruction.
Protective cover may stay on during framing, but must be

removed before fi nal fi nishing. Once fi nal fi nishing has been

completed, the protective cover can be used to protect the

heater until fi nal installation is complete.

C. Clearance to Combustibles

Sides . . . . . . . . . . . . . . . . . . . . . . . . . . .0 in. (0 mm)
Floor . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 in. (0 mm)
Top . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 in. (0 mm)
Back . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 in. (0 mm)

D. Framing

• Choose a fireplace location and frame as shown in

Figure 2.1.

• Frame in the fi replace with a header across the top.

• It is important to allow for fi nished face when setting the

depth of the frame.

• If a hearth system or raised hearth is to be installed, the

unit MUST be raised to provide service access and use

of optional fronts.

• The fi replace can now be positioned in the opening.

• Level it with shims if necessary, and attach the unit to the

frame using the nailing fl anges provided.

F. Hardwire Electrical Connections

Note: All wiring must be completed prior to fi nishing the

unit.
For supply connections use No. 14 AWG or larger wires. Use

copper wire only. Connect only to a 15 AMP branch circuit.

A dedicated circuit is recommended as other appliances on

the circuit may cause the breaker to trip or fuse to blow

when the heater is operating.
• Remove the screws securing the junction block cover.

• Wire to a properly grounded, 120 volt, 60 Hz, 15 AMP

circuit

• Ensure all junction block connections are tight.

• Replace the cover and retaining screws.

• Plug in the IEC-320-C14 power plug to the IEC-320-C13

power inlet located on the upper right side of the unit.

• All components and wiring may be inspected by removing

the top inter-panel through the fi replace front opening.

G. Wall Switch and Thermostat Connections

The Optional Wall Switch 4050-309 contains two single pole

switches. (LEVITON 5634 Series or equal)
The Optional Wall Thermostat is a low voltage mechanical

type. (Columbus Electric RK120EAA or equal)
Maximum run distance is 30 ft. (9.14 m) with 20 gauge

solid copper low voltage thermostat wire. Connect per the

electrical wiring diagram on page 7.

H. Finishing

Combustible or non-combustible materials may be used to

fi nish up to the fi replace opening.
Note: ensure that you leave adequate room to remove and

replace the front screen or optional front.

WARNING! Do NOT use this appliance if any part has

been under water. Immediately call a qualifi ed service

technician to inspect and to replace any part of the electri-

cal system if necessary.

E. Electrical Specifi cations

Voltage . . . . . . . . . . . . . . . . . . . . . . 120 V AC, 60 Hz
Total Amps . . . . . . . . . . . . . . . . . . . . . . . . . .9.6 AMP
Total Watts . . . . . . . . . . . . . . . . . . . . . . . 1050 Watts
Heater Rating . . . . . . . . . . . . .1000 Watts/3415 BTU

WARNING! Electrical wiring must comply with local

building codes and other applicable regulations to

reduce the risk of fi re, electrical shock and injury.

WARNING! Do NOT connect the optional low voltage

switch and/or thermostat to 120 volt branch circuit.