Insert coin cell battery in thermostat, Thx9421 installation, Thx9321 installation – Honeywell PRESTIGE THX9321 User Manual

Page 13

Advertising
background image

THX9321 PRESTIGE

®

2.0 AND THX9421 PRESTIGE

®

IAQ WITH EIM

13

68-0311—02

4. Remove the wallplate from the wall and, if drywall, drill

two 3/16-in. holes in the wall, as marked. For firmer

material such as plaster, drill two 7/32-in. holes. Gently

tap anchors (provided) into the drilled holes until flush

with the wall.

5. Position the wallplate over the holes, pulling wires

through the wiring opening. See Fig. 18.

6. Insert the mounting screws into the holes and tighten.

Fig. 18. Mounting wallplate (THX9421).

Insert Coin Cell Battery in Thermostat

Place coin cell battery in thermostat. Be sure to follow polarity

markings on thermostat. See Fig. 19.

NOTE: Coin cell battery saves time and date during a

power loss.

Fig. 19. Insert coin cell battery (THX9421)

THX9421 Installation

INSTALLATION WITH EQUIPMENT INTERFACE MODULE

(EIM)

1. Wire to C and R terminals of the EIM or to a separate 24

volt transformer (not provided). See Fig. 20.

2. Snap thermostat onto wallplate after wiring is complete.

INSTALLATION WITH TRUEZONE WIRELESS ADAPTER

1. Wire to C and R terminals of the TrueZONE panel or to a

separate 24 volt transformer (not provided). See Fig. 20.

2. Snap thermostat onto wallplate after wiring is complete.

THX9321 Installation

THERMOSTAT WIRED DIRECTLY TO THE HVAC

EQUIPMENT OR ZONE PANEL

1. Refer to “THX9321 Thermostat Wiring Diagrams” begin-

ning on page 141.

2. Snap thermostat onto wallplate after wiring is complete.

INSTALLATION WITH EQUIPMENT INTERFACE MODULE

(EIM)

1. Connect power and common from the EIM to the Rc and

C terminals at the thermostat or use a separate 24 volt

transformer (not provided) to power the thermostat.

2. Snap thermostat onto wallplate after wiring is complete.

NOTE: Note: When the THX9321 thermostat is used with

an EIM, the relays in the thermostat do not func-

tion.

INSTALLATION WITH TRUEZONE WIRELESS ADAPTER

1. Connect power and common from the TrueZONE panel

to the Rc and C terminals at the thermostat or use a sep-

arate 24 volt transformer (not provided) to power the

thermostat.

2. Snap thermostat onto wallplate after wiring is complete.

NOTE: When the THX9321 thermostat is used with a

TrueZONE Wireless Adapter, the relays in the

thermostat do not function.

Fig. 20. Inserting wires in thermostat terminal screws

(THX9421).

MCR34688

R

C

1324

Advertising
This manual is related to the following products: