Connecting station modules – Hunter Fan ICC-801PL User Manual

Page 15

Advertising
background image

11

CONNECTING STATION MODULES ......................................................................................

The ICC controller is supplied with one factory-installed station module
for up to 8 stations. Additional modules may be added in increments of
4 or 8 stations to expand the controller’s station capability (maximum
of 32 stations with plastic cabinet and a maximum of 48 stations with
metal or stainless steel cabinet). Additional modules are purchased
separately.

1. When installing additional modules, you will need to turn off the AC

power to the controller. You should also temporarily remove the 9
volt battery if one is being used.

2. Snap the module into the appropriate sequential position in the

back of the controller. NOTE: If you are using a 4 station module, it
must be in the last sequential position on the controller. Example:
For an area that needs 12 stations, the first module will
be an 8 station and the 4 station module will be below it. Note that
the station numbers are identified on the back panel, not the
individual modules.

3. Once all modules are snapped into place, reactivate power to the

controller and reinstall the battery. Turning the power off and then
on again permits the microprocessor to recognize the newly
installed modules.

NOTE: Each module has a place for connection of a
field common wire. For systems with a single
common, you only need to connect the common
wire to any single common terminal.

Advertising
This manual is related to the following products: