Connecting a master valve – Hunter Fan ICC-801PL User Manual

Page 17

Advertising
background image

13

Common Wire

Master Valve

Master

Valve

Wire

Power Module

CONNECTING A MASTER VALVE .........................................................................................

NOTE: Complete this section only if you have a
master valve installed. A master valve is a
normally closed valve installed at the supply point
of the main line that opens only when the auto-
matic system is activated.

1. At the Master Valve, attach the common wire to either solenoid wire

of the valve. Attach a separate control wire to the remaining
solenoid wire.

2. Route the wires into the controller via the field wire conduit.

3. Connect either wire from Master Valve to the P/MV terminal.

Connect remaining wire to the C (Common) terminal.