Power Module

Weather Sensor

CONNECTING A WEATHER SENSOR (NOT INCLUDED) ...................................................

A Hunter Mini-Clik

®

rain sensor or other type of micro-switch weather

sensor may be connected to the ICC. The purpose of this sensor is to
stop watering when precipitation is sufficient. The sensor connects
directly to the controller and allows you to easily override the sensor by
using the Rain Sensor bypass switch on the controller.

1. Route the wires from the rain sensor up through the same conduit

used for valve wiring.

2. Remove the jumper from the two SEN terminals on the power

module.

3. Connect one wire to the SEN terminal and one to the other SEN

terminal on the power module

NOTE: If the rain sensor switch is left in the ACTIVE
position and no sensor is connected, and the
jumper has been removed, the display will read
SEN OFF and no irrigation will occur. To eliminate
this problem when no sensor is connected, leave
the switch in the BYPASS position or install a short
jumper wire between the sensor terminals.

For more information on Mini-Clik

®

sensors, visit Hunter's Website at

http://www.HunterIndustries.com or contact your local dealer.