Setting the Soak Times

It is only necessary to set a SOAK time if the accumulated CYCLE times
on any single program will not provide an adequate soak time. For
instance, if the sum of the cycle times for all stations in a program
exceeds 10 minutes and each station will require no more than 20
minutes of soak time, then the accumulated cycle times are sufficient
and no soak time will need to be programmed. However, if the
necessary soak time did exceed the 10 minutes, then a soak time must
be entered for those stations requiring a longer soak between
waterings. The soak time default is 10 minutes.

Pressing the

button at any time while in the cycle time setup will

allow the user to enter the soak time setup for that station. Pressing

again will go back to the cycle time setup. The soak time works

identically to the cycle time setup except that the SOAK icon will be on
as opposed to the CYCLE icon.

NOTE: If the dial is moved from the SET STATION
RUN TIMES position, then the entire sequence of
going back to RUN and holding the

key down

must be repeated to reenter the cycle and soak
setup. The cycle and soak feature is a station
dependent function and will be used whenever the
station operates regardless of which program or
programs the station is assigned.

1. Start with the dial in the RUN

position.

2. Press and hold the

button

down while turning the dial to
the SET STATION RUN TIMES
position.

3. Release the

button. At this

point the display will show a
delay time for all stations in
seconds, which will be
blinking. The DELAY icon shall
also be lit at this time.

4. The display will show “SEC”.

Use the

and

buttons to

increase or decrease the delay
time between 0 and 10 minutes
in 1 second increments.

5. Pressing either the

button

or the

button will allow for

programming a longer delay
between stations. The display
will show the delay in minutes.

6. Press the

and

buttons

to increase or decrease the
delay time from 0 to 10 hours
in 5 minute increments.

7. Return the dial to the RUN

position.

DELAY

2. Programmable Delay Between Stations

This feature allows the user to insert a delay between when one station
turns off and the next station turns on. This is very helpful on systems
with slow closing valves or on pump systems that are operating near
maximum flow or have slow well recovery.