Control Keypad

71(96)

7

Figure 7-11. Parameter locking

7.4.7.3

Keypad settings

In the submenu S6.6 under the System menu you can further customise your frequency converter
operator interface.

Locate the Keypad settings submenu (S6.6). Under the submenu, there are two pages (P#)
associated with the keypad operation, Default page (P6.6.1) and Timeout time (P6.6.3)

Default page (P6.6.1)

Here you can set the location (page) to which the display automatically moves as the Timeout time
(see below) has expired or as the power is switched on to the keypad.

Press the Menu button right once to enter the edit mode. Pressing the Menu button right once again
makes you able to edit the number of the submenu/page digit by digit. Confirm the new default page
value with the Enter button. You can return to the previous step anytime by pushing the Menu button
left
.

Note! If you set a page that does not exist in the menu, the display will automatically move to the last
available page in the menu.

Figure 7-12. Default page function