Heatilator • GDST3831I • 2127-900 Rev. L • 3/13

28

H

2

H

1

V

2

V

1

Figure 7.6

1. Top Vent - Horizontal Termination - (continued)

Three Elbows

V

1

Minimum**

H

1

+ H

2

Maximum

V

2

V

1

+ V

2

Min.

90 Elbow**

2 ft.

610 mm

*

*

1/2 ft.**

152 mm

6 ft.

1.8 m

*

*

1-1/2 ft.**

457 mm

10 ft.

3 m

*

*

2-1/2 ft.**

762 mm

12 ft.

3.7 m

*

*

3-1/2 ft.

1.1 m

14 ft.

4.3 m

*

*

H

1

+ H

2

Max. =14 ft. (4.3 m)

*No specifi c restrictions on this value

EXCEPT V

1

+ V

2

+ H

1

+ H

2

cannot exceed 40 ft. (12.2 m)

See Warning Below**

Note: There MUST be a 25%
reduction in total H when using
fl ex vent except when using the
simple up and out installation
(see Figure 7.3).

WARNING**

Fire Risk.

• When using SLP-HRC-SS and SLP-HRC-ZC-SS

termination caps on top vented fi replaces, a one
foot minimum vertical vent section is required before

installing fi rst elbow

.

• When using DVP-TB1 termination cap on top vented

fi replaces, a three foot minimum vertical vent section
is required before installing fi rst elbow.

• When using any other cap, a section of vertical pipe (12 inches

minimum) MUST be installed prior to attaching a 90° elbow.