B. Clearances

WARNING! Risk of Fire! You must comply with all minimum air space clearances to combustibles as specified in Fig-

ure 6.2.

DO NOT pack required air spaces with insulation or other materials.

Heatilator • SC60 • 32838 • Rev AG • 7/12

(insulation)

0 in. to level

of standoffs

Attic

Insulation

Shield

(ceiling)

(roof)

(attic)

(ceiling)

Ceiling Firestop

Offset/Return (secured

with hanger straps)

Storm Collar

Roof Flashing

1/2 in. (13 mm) to back &

sides of appliance,

and at nailing flanges

Must have 2 in. (51 mm)

minimum clearance

to header

0 in.

to floor

2 in. (51 mm) min.

Shaded areas

represent

2 in. (51 mm) min.

air space clearance

required around pipe

Combustible Object

48 in.

1219 mm

Figure 6.2 Clearances to Combustible Materials

Note: Chimney air kit is not shown, but is required in Canada.