Heatiator Heatilator Wood Burning Fireplace SC60 User Manual

Page 34

Advertising
background image

34

Heatilator • SC60 • 32838 • Rev AG • 7/12

Chimney

Pipe

Chase Top

Termination Cap

Chase

Collar

2 in. (51 mm)

Minimum Height

Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm).

Place waterproof sealer under

each flange of the termination

cap and on top of each screw

to help prevent leaks.

2 in. (51 mm)

maximum

4 3/4 in. (121 mm)

maximum

The last section of pipe must

stop between 2 in. (51 mm)

above the top of the chase and

4 3/4 in. (121 mm) below the

top of the chase.

Figure 9.7 Installing a TS345/TS345P Square Termination Cap

• TS345/TS345P Square Termination Cap

Chimney

Pipe

Chase Top

Termination Cap

Chase

Collar

2 in. (51 mm)

Minimum Height

Remove 2 screws

from front & back

to lift the top off

Termination cap pipe and chimney section must overlap

1-1/2 in. (38 mm)

Place waterproof sealer

under each flange of the

termination cap and on

top of each screw to

help prevent leaks.

The last section of pipe

must stop between 2 in.

(51 mm) above top of

chase and 7 in. (178 mm)

below top of chase

2 in. (51 mm)

7 in. (178 mm)

Figure 9.8 Installing a TCT375 Terra Cotta Cap

• TCT375 Terra Cotta Cap

Advertising